Installing the Chassis Rails

Position the fixed chassis rail sections you just removed along the side of the chassis making sure the five screw holes line up.
Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure

2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets
when installing into a telco rack.

Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the
server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended  from the rack. This prevents  the server from coming completely out of the rack when you
pull it out for servicing.

Summary of Contents for RMC 7155

Page 1: ...d Product description and product specifications are subject to change without notice For latest product information please visit Acnodes web site at www acnodes com RMC 7152 14 short depth serverRMC 7152 14 short depth server 1 RMC 7155 14 short depth server Installation Guide RMC 7155 14 short depth server with two Intel Xeon processors ...

Page 2: ...ack with the rack rails provided with the system You should also refer to the installation instructions that came with the rack unit you are using Basic Installation Procedure You should have received two rack rail assemblies with the RMC 7152 Each of these assemblies consist of two sections an inner fixed chassis rail that secures to the unit A and an outer fi xed rack rail B that secures to the ...

Page 3: ...ssis making sure the five screw holes line up Note that these two rails are left right specific Screw the rail securely to the side of the chassis see Figure 2 2 Repeat this procedure for the other rail on the other side of the chassis You will also need to attach the rail brackets when installing into a telco rack Locking Tabs As you have seen both chassis rails have a locking tab which serves tw...

Page 4: ... in the rack keeping the sliding rail guide facing the inside of the rack Screw the assembly securely to the rack using the brackets provided Attach the other assembly to the other side of the rack making sure that both are at the exact same height and with the rail guides facing inward Installing the Server Into the Rack You should now have rails attached to both the chassis and the rack unit The...

Page 5: ...b site at www acnodes com RMC 7152 14 short depth serverRMC 7152 14 short depth server 5 RMC 7155 14 short depth server Installing the Server into a Telco Rack If you are installing the RMC 7152 into a Telco type rack follow the direc tions given on the previous pages for rack installa tion The only difference in the installation procedure will be the positioning of the rack brackets to the rack T...

Reviews: