1.
Turn off the mains power.
2.
Loosen all the screws (AB)
,
open the cover (C).
3.
Loosen the screws (D).
4.
Unplug all the connect wires over the belt.
5.
Change a new belt (E), put the belt around the axis gear and motor gear.
6.
Plug all the connect wires back upon the belt.
7.
Tighten all the screws.
D
F. If The tilt belt is broken
1.
Turn off the mains power.
2.
Loosen all the screws (AB).
3.
Loosen the screws (C) that fix the bridge.
4.
Change a new belt (D). Please adjust the tension of the belt properly. Note: do not fix the belt too
tight as it is can easily rupture.
5.
Reverse the procedures from step 3 to 2.