CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be
opened!
4.2 Light Source
PHILIPS MSD Platinum 20R
For non replacable lightsources:
"The light source of this luminaire is not replaceable; when the light source reaches its end of life
the whole luminaire shall be replaced".
Because of its high internal pressure, there might be a risk that the Discharge lamp would
explode during operation. The lamp emits intense UV radiation which is harmful to the
eyes and skin. The high luminance of the arc can cause severe damage to the retina if you
take a close look at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX controller)
and let the unit run at least five minutes to cool down before switching off the mains
supply. Never handle the lamp or luminary when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do not
use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection.
5. How To Set The Unit
5.1 Main Function
Turn on the unit, press the
MENU
button into menu mode, and press the
UP
/
DOWN
button until the
required function is shown on the monitor. Select the function by the
ENTER
button. Use the
UP
/
DOWN
button to choose the submenu, press the
ENTER
button to store and automatically return
to the last menu. Press the
MENU
button or let the unit idle one minute to exit menu mode.
In the event of disconnecting with mains power, press the
UP
button for one minute to enter into
menu mode. Press MENU button or let the unit idle one minute to exit.
The main functions are shown below
(
the grayed boxes are preset settings
)
:
7A