6. Control By Universal DMX Controller
6.1 Connection
1.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor
between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last
unit.
2.
Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the
input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very
high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily
distort the signal and shut down the system.
3.
The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of
the units’ power is disconnected.
4.
Each lighting unit needs to have a DMX address to receive the data by the controller. The address
number is between 0-511 (usually 0 & 1 are equal to 1).
ATTENTION
Termination reduces signal errors and to avoid signal transmission problems and
interference. It is always advisable to connect a DMX terminal (Resistance 120 ohm 1/4W
between pin2 (DMX-) and pin3 (DMX+) of the last fixture).
23D