15- 

from 1 to 512 channels so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 

address. Once the address has been selected, press and keep 

ENTER

 button pressed up 

to when the display stops blinking or storing automatically 8 seconds later. To go back to 

the functions without any change press the

 MENU

 button again.   

Please refer to the following diagram to address your DMX512 channel for the first 4 units.   

 

6 Channels

   

 

 

 

 

 

 

 

 

7.4 DMX512 Configuration 

 

 

XP-1200F 

                                                                                                                                                                                                         

4- 

y

  Avoid any inflammable liquids, water or metal objects entering the unit. Once it happen, 

cut off the mains power immediately. 

y

  Do not operate in dirty and dusty environment, also cleaning fixtures regularly. 

y

  Do not allow children to operate the fixture. 

y

  Do not touch any wire during operation as there might be a hazard of electric shock. 

y

  Avoid power wires together arounding other cables. 

y

  The minimum distance between light output and the illuminate surface must be more 

than 2.5 meters. 

y

  Disconnect mains power before fuse/lamp replacement or servicing. 

y

  Replace fuse/lamp only with the same type. 

y

  In the event of serious operating problem, stop using the unit immediately.   

y

  Never turn on and off the unit time after time. 

y

  The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly 

damaged. 

y

  Do not open the unit as there are no user serviceable parts inside. 

y

  Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead 

to damage or malfunction. Please contact the nearest authorized technical assistance 

center.  

y

  Disconnect the mains power if the fixture is not used for a long time. 

y

  Do use original packing materials once transport it again. 

 

Caution 

y

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

y

  Hot lamp explosion hazard. Do not open the unit within 15 minutes after switching off. 

y

  Do replace the bulb once it is damaged, distortion or over lifespan. 

y

  Do not look directly at the light while the bulb is on. 

y

  Never touch bulb with bare fingers, as it is very hot after using. 

y

  Do not start on the unit without bulb enclosure or when housing is damaged. 

 

Product Items   

y

 User 

manual 

y

  2 x Omega clamps 

Summary of Contents for XP-1200F

Page 1: ...6 x 30 mm Glass T15A Lamp MSI 1200W S HMI 1200 S K SFc10 4 Dimension 1170 x 330 x 225 mm 405 x 360 x 35 mm Controller Weight 42 4 kg Innovation Quality Performance Professional Intelligent Follow Spo...

Page 2: ...nce with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN 55103 1 1996 EN 55103 2 1996 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 Harmonized Standard EN 60598 2...

Page 3: ...optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty su...

Page 4: ...erature is higher than this y Don t connect the device to any dimmer pack y During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device...

Page 5: ...must be more than 2 5 meters y Disconnect mains power before fuse lamp replacement or servicing y Replace fuse lamp only with the same type y In the event of serious operating problem stop using the...

Page 6: ...FIXED COLOURS RAINBOW switch Turning the switch on the COLOR SCROLL position enable the rainbow function you can set different rainbow speed by pressing COLOUR buttons from slow to fast Turning the sw...

Page 7: ...d 7 2 Dedicated Controller IF series has 6 channels for international protocol DMX512 It can finish all operations via dedicated controller without using other controllers When the power is switched o...

Page 8: ...hout any change after 8 seconds Dimmer offset Press the MENU button for at least 5 seconds into offset mode use DOWN and UP button up to when the is shown on the display Pressing ENTER button and the...

Page 9: ...the MENU button for at least 5 seconds into offset mode use DOWN and UP button up to when the is shown on the display Pressing ENTER button and the display will XP 1200F 8 5 Lamp MSI 1200W S HMI 1200...

Page 10: ...eset DMX 512 Address Setting Press the MENU button until the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the add...