ACME VQ080ESa Instructions Download Page 2

 

CEILING VENTILATOR

 

 

 

 

TYPICAL INSTALLATIONS

 

 

 

 

 

 

 

 

 

 

  

6” 

 

 

 

 

 

6” 

Housing mounted  to I -joists .

 

 

For a more quiet and efficient fan locate fan where the shortest 
duct run and a minimum number of elbows will be needed. 

Use a roof cap or wall cap that has a built-in damper to reduce 
backdrafts. 

 

 

 

 

 

 
 
Housing mounted to joists.

 

INSTALL HOUSING 

 

 

1a. Mount housing to joist or I-joist. 

Hold housing in 

place so that the housing contacts the bottom of the joist. 
The housing mounts with two(2) screws or nails. Screw or 
nail housing to joist through the holes in each mounting 
flange.

 

 

 

 

 

 

 

 

 

 

 

Housing mounted to truss.

 

 

PLAN THE INSTALLATION  

 

 

 

OR

 

 

1b. Mount housing anywhere between 

trusses, joists, or I -joists using hanger 

bars.

 

Sliding hanger bars are provided to allow for accurate 

positioning of housing anywhere between framing. They 
can be used on all types of framing (I-joist, standard joist, 

and truss construction) and span up to 24”.

 