1. Safety Introductions   

 

 

 

WARNING 

 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be 
sure that they also receive this instruction booklet. 

 

All fixtures are intact from the manufacturer, please operate follow up the user manual, 
artificial fault are not under guarantee repair. 

 

Unpack and check carefully that there is no transportation damage before using the unit. 

 

The unit is for indoor use only. Use only in a dry location. 

 

Do install and operate by operator. 

 

Use safety chain when fixes the unit. Don’t handle the unit by taking its head only, but always 
by taking its base. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 
surfaces.   

 

Be sure that no ventilation slots are blocked, otherwise the unit will be overheated. 

 

Before operating, ensure that the voltage and frequency of power supply match the power 
requirements of the unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature TA : 40

. Don’t operate it where the temperature is higher 

than this. 

 

Don’t connect the device to any dimmer pack. 

 

First run, there will be smoke or smells, and all disappearing a few minutes later. 

 

Make sure there are no flammable materials close to the unit while operating, as it is fire 
hazard. 

 

Look over power wires carefully, replace immediately if there is any damage. 

 

Never run on for a long time lest shortening lifespan. 

 

Avoid any inflammable liquids, water or metal objects entering the unit. Once it happen, cut 
off the mains power immediately. 

 

Do not operate in dirty and dusty environment, also cleaning fixtures regularly. 

 

Do not allow children to operate the fixture. 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

2A 

Summary of Contents for MP-90 RGBW

Page 1: ...MP 90 RGBW User Manual Please read the instructions carefully before use...

Page 2: ...4 3 How To Set The Fixture 4 3 1 Control Panel 4 3 2 Main Function 5 4 How To Control The Unit 10 4 1 Master Slave Built In Preprogrammed Function 10 4 2 DMX Controller 10 5 DMX512 Configuration 12 6...

Page 3: ...g ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum a...

Page 4: ...orized technical assistance center Disconnect the mains power if the fixture is not used for a long time Do use original packing materials once transport it again Do not look directly at the LED light...

Page 5: ...PCS White 24PCS Fuse T 6 3A Power consumption 280W Dimension 234 x 299 x 265 mm Weight 7 9kg pcs 3 How To Set The Fixture 3 1 Control Panel 1 Display To show the various menus and the selected functio...

Page 6: ...e to input DMX signal 7 Mains input Connect to supply mains power for the next unit 3 2 Main Function To select any functions press MENU button until the required one is shown on the display Select th...

Page 7: ...6A...

Page 8: ...link Use DOWN and UP button to select the Master Slave 1 or Slave 2 mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any chang...

Page 9: ...ER button to setup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button Sound Sense Press the MENU button up to when...

Page 10: ...p or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button Manual setting color Press the MENU button up to when is...

Page 11: ...ove all the motors to their home position After that the unit will be ready to receive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed Function By linking the units in...

Page 12: ...ay stops blinking or storing automatically one minute later To go back to the functions without any change press the MENU button again If you use please refer to the following diagram to address your...

Page 13: ...5 DMX512 Configuration Mode 4 5 Mode 7 12A...

Page 14: ...h to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor...

Page 15: ...controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 1 Wrong DMX address in the fixture Set the proper...

Page 16: ...accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Stan...

Reviews: