background image

12A 

 

No need to turn the unit off when you change the DMX address, as new DMX address 

setting will be effected at once. Every time you turn the unit on, it will show type on the 

display and move all the motors to their ‘home’ position and you may hear some noises for 

about 20 seconds. After that the unit will be ready to receive DMX signal or run the built-in 

programs. 

 

  5.1 Master/Slave Built-In Preprogrammed Function   

You can select blackout mode 

 in 

  (yes blackout) or 

 (no blackout) 

mode while the unit is turned on. By linking the units in master/slave connection, the first unit 

will control the other units to give an automatic, sound activated, synchronized light show. 

This function is good when you want an instant show. You have to select 

 (show 1) 

or 

  (show 2) or 

 (show 3) or 

  (show 4) mode by easy controller. Its 

DMX input jack will have nothing plugged into it, and Its master LED will be constantly on 

and sound LED will flash to the music. The other units will have to set in slave mode 

 and select 

 (normal) or 

 (2 light show) mode, Their DMX cables 

plugged into the DMX input jacks (daisy chain) and the slave LED lights will constantly on. 

 

2-light show 

In 

 (slave mode), 

  means the unit works normally and 

 means 

2-light show. In order to create a great light show, you can set 

  on the second unit to 

get contrast movement to each other, even if you have two units only. 

 

  5.2 DMX Controller   

Use universal DMX controller to control the units, you have to set DMX address from 1 to 

512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 

address. Once the address has been selected, press and keep 

ENTER

 button pressed up to 

when the display stops blinking or storing automatically 8 seconds later. To go back to the 

functions without any change press the

 MENU

 button again. Please refer to the following 

diagram to address your DMX512 channel for the first 4 units.   

 

13A 

 

5.3 DMX512 Configuration   

* MH-666S without Channel 8 – Focus.

 

 

NOTE:

 Shutter function is viable only when the value of channel 4 is between 0 and 18. 

Summary of Contents for MH-6616S

Page 1: ...Specification 2 1 Inserting Exchanging rotating gobos 2 2 Beam angel 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Universal DMX Controller 5 3 DMX512 Configuration 5 4 DMX512 Connection 6 Troubleshooting 7 Fixture Cleaning ...

Page 2: ... serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts y Don t connect the device to any dimmer pack or power pack y Do not touch any wire during operation as high voltage might ...

Page 3: ...universal DMX controller MH 6616S MH 666S Channel 1 Pan motion Pan motion Channel 2 Tilt motion Tilt motion Channel 3 Shutter Shaking Shutter Shaking Channel 4 Gobo Gobo Channel 5 Color Color Channel 6 Gobo Rotation Gobo Rotation Channel 7 Channel 8 Focus 5A Dimension 360mm x 397mm x 503mm MH 6616S 373mm x 295mm x 451mm MH 666S Weight 26 kg MH 6616S 13 kg MH 666S 2 1 Inserting Exchanging rotating ...

Page 4: ...he risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot Adjust lamp position by screws A B and C MH 666S In case of replacement of the lamp or maintenance do not open the fixture within 15 minutes until the unit cools down after switching off MH 6...

Page 5: ...8 seconds To go back to the functions without any change press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 mode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angel left to right to left 160 Tilt mov...

Page 6: ...main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Display Inversion It is good for you to install the unit on the floor or under ceiling Press the MENU button up to 11A when the is blinking on the display Use the ENTER button to change to the mode display inversion It will automatically store after 8 seconds Or press the EN...

Page 7: ...slave mode and select normal or 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave LED lights will constantly on 2 light show In slave mode means the unit works normally and means 2 light show In order to create a great light show you can set on the second unit to get contrast movement to each other even if you have two units only 5 2 DMX Controller Use u...

Page 8: ...ms that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED...

Page 9: ...Put the belt around the axis gear and motor gear 9 Plug all the connect wires C that form the arm to PC board and igniter 10 Adjust the pan home position 11 Screw the base housing cover B 17A 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixt...

Page 10: ...95 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements 19A Technical Specifications MH 6616S Power AC 120V 60Hz or AC 230 240 250V 50 60Hz Fuse 20mm Glass T10A Fast Blow Lamp MSD 250 2 Dimension 360mm x 397mm x 503mm Weight 26 kg MH 666S Power AC 120V 60Hz or AC 230 240 250V 50 60H...

Reviews: