Installation:   

The   unit   should   be   mounted   via   its   screw   holes   on   the   bracket.   Always   ensure   that   the   unit   is   
firmly    fixed    to    avoid    vibration    and    slipping    while    operating.    Make    sure    that    the    structure    to   

which    you    are    attaching    the    unit    is    secure    and    is    able    to    support    a    weight    of    10    times    of    the   

unit’s    weight.    Also    always    use    a    safety    cable    that    can    hold    12    times    of    the    weight    of    the    unit   
when   installing   the   fixture.       

The   equipment   must   be   installed   by   professionals.   It   must   be   installed   in   a   place   where   is   out   of   
the   reach   of   people   and   no   one   can   pass   by   or   under   it.   

   

2.   Technical   Specifications

   

 

5   DMX   Channels:   Pan,   Tilt,   Gobo/Colour,   Strobe,   Dimmer   

 

8   gobos   with   dichroic   colours   plus   open   

 

Smooth   0~100%   dimming   and   various   strobe   effects   

 

3   Operation   Modes:   DMX,   Master/Slave   and   Sound   Activation   

 

Built-­‐in   shows   in   master/slave   mode   triggered   by   the   music   

 

Optional   easy   controller   CA-­‐8       

 

Power   Voltage:                                           

AC   100~240V,   50/60Hz   

 

Power   Consumption:

                        52W   

 

Power   Cable   Daisy   Chains:       

11   Fixtures   Max.   (230V,   50Hz)   

                                                                                                            7   Fixtures   Max.   (120V,   60Hz)

   

 

LED   Source:

                                                        1   x   25W   CREE   LED   

 

Weight:

                                                                    3.5kgs   

 

Dimensions:                                                   

338   x   168   x   196   mm   

   

Summary of Contents for LED-SC25

Page 1: ...LED SC25 User Manual Please read the instructions carefully before use ...

Page 2: ...Specifications 3 3 How To Control The Unit 4 3 1 Control Panel 4 3 2 Master Slave Operation 5 3 3 Easy CA 8 Controller 5 3 4 Universal DMX Controller 6 4 DMX 512 Configuration 7 5 DMX 512 Connection 7 6 Troubleshooting 8 7 Cleaning and Maintenance 9 ...

Page 3: ...s close to the unit while operating as it is a fire hazard Use safety cables when installing this unit Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than this Turn off the power and allow about 5 minutes for the unit to cool down before servicing In the event of a serious operating problem stop using the unit immediately Never try to repair the un...

Page 4: ...nstalled by professionals It must be installed in a place where is out of the reach of people and no one can pass by or under it 2 Technical Specifications 5 DMX Channels Pan Tilt Gobo Colour Strobe Dimmer 8 gobos with dichroic colours plus open Smooth 0 100 dimming and various strobe effects 3 Operation Modes DMX Master Slave and Sound Activation Built in shows in master slave mode triggered by t...

Page 5: ... to the next fixture 4 DMX IN DMX 512 link use 3 pin XLR cables to link the fixture to a DMX controller 5 Microphone Used to receive music for sound activation 6 Only for remote control Used to connect to the CA 8 to control the unit in Stand by Function and Mode 7 Only for wireless receiver Used to connect to the CA 9 RX to control the unit in Stand by Function and Mode ...

Page 6: ...lave units DMX start address may have any value but NOT 001 example set the first 3 DIP switches to ON 3 3 Easy CA 8 Controller The easy CA 8 remote control is used only in master slave modes By connecting to the remote socket of the first unit you will find that the remote controller on the first unit will control all the other units in Stand by Function and Mode Stand by Blackout the unit Functi...

Page 7: ...1 to 9 Dip switch 10 is used to choose the channel mode Please refer to the following diagram to show how to address your DMX 512 system using the binary code DMX 512 Address Chart Dip switches 1 2 3 4 5 6 7 8 9 10 Value 1 2 4 8 16 32 64 128 256 N A Examples Unit 1 dip on 1 1 Unit 2 dip on 2 3 2 4 6 Unit 3 dip on 1 2 4 1 2 8 11 Unit 4 dip on 5 16 ...

Page 8: ...7 4 DMX 512 Configuration 5 Channels Mode 5 DMX 512 Connection ...

Page 9: ... set to receive the data sent by the controller The address number is between 0 512 usually 0 1 are equal to 1 5 The end of the DMX 512 system should be terminated to reduce signal errors 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 6 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixtu...

Page 10: ...l 2 Check the microphone by tapping it 7 Cleaning and Maintenance Cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates moist smoky or particularly dirty surroundings can cause a greater accumulation of dirt on the fixture Clean with lint free cloth using normal glass cleaning liquid or mild soapy water Clean ...

Page 11: ...nce with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 12: ...11 Innovation Quality Performance ...