ACME LED-BR10 User Manual Download Page 5

 

 

8- 

1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin 

adapter-cable. 

2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 

ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug 

and plug it in the DMX-output of the last unit. 

3. Connect the unit together in a ‘daisy chain’ by XLR plug from the output of the unit 

to the input of the next unit. The cable can not be branched or split to a ‘Y’ cable. 

DMX 512 is a very high-speed signal. Inadequate or damaged cables, solder 

joints or corroded connectors can easily distort the signal and shut down the 

system. 

4. The DMX output and input connectors are pass-through to maintain the DMX 

circuit, when power is connected to the unit. 

5. Each lighting unit needs to have an address set to receive the data sent by the 

controller. The address number is between 0-512 (usually 0 & 1 are equal to 1). 

6. The end of the DMX 512 system should be terminated to reduce signal errors. 

7. 3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 

                    Pin 4/5: Not used. 

 

 

7. Troubleshooting   

Following are a few common problems that may occur during operation. Here are some 

suggestions for easy troubleshooting: 

 

A.  The fixture does not work, no light   

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and 

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

 

 

9-

of the fixture or the previous one. 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

 

C. Some fixtures don’t respond to the easy controller   

1.  Check the LED for the response of the master/ slave mode signal. 

2.  Check if the unit is receiving DMX signal and cut it off.   

 

D. No response to the sound 

1.  Make sure the fixture does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone. 

 

E. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition. 

 

 

8. Fixture Cleaning   

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause 

greater accumulation of dirt on the unit’s optics. 

y

  Clean with soft cloth using normal glass cleaning fluid. 

y

  Always dry the parts carefully. 

y

  Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 

 

 

 

 

 

 

Summary of Contents for LED-BR10

Page 1: ...LED BARREL LED BR10 User Manual Professional Entertainment Technology Широкий ассортимент оборудования ACME на www maxlight ru ...

Page 2: ...tilation slots are blocked y Disconnect mains power before fuse replacement or servicing y Replace fuse only with the same type y Make sure there are not flammable materials close to the unit while operating as it is fire hazard y Use safety cable when fixes this unit y Maximum ambient temperature is TA 40 and don t operate it where the temperature is higher than this y Unit surface temperature ma...

Page 3: ...supply for next 20 units 5 4 How To Control The Unit 4 1 Control Panel 1 Dip switches For different function setting 2 Only for remote control Connecting with CA 8 CA 9 CA 9RTX to control the unit for Stand by Function and Mode function 3 DMX output For DMX512 link use 3 5 pin XLR plug cable to link the next unit 4 DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal 5 Power Co...

Page 4: ...ut the unit Function 1 Synchronous Strobe in white 2 Sound strobe in white 3 Sound Strobe in color Select Color Select Show 1 6 Mode Strobe LED OFF Show LED ON LED blinking Dip switches setting Channel 1 6 11 16 ON ON ON ON 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 7 5 DMX 512 Configuration 5 Channel mode DMX Configuration Pan Barrel Strobe Color Dimmer 00...

Page 5: ...use 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB 9 of the fixture or the previous one 4 Try to...

Page 6: ...rovision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance ...

Reviews: