ACME LED-275 D User Manual Download Page 8

 

7- 

 Slave Mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

 (master) or 

 (slave 1) or 

  (Slave 2) mode.

 

Once select, press the 

ENTER

 button to setup or automatically exit 

menu mode without any change after 30 seconds. To go back to the functions without any 

change press the 

MENU

 button

 

 Show Mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

  (Random show) or 

 (show 

1) or 

 (Show 2) or … or 

 (show 6).

 

Once select, press 

ENTER

 button to 

setup or automatically exit menu mode without any change after 30 seconds. To go back to 

the functions without any change press the 

MENU

 button

 

 Sound Mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

 (sound on) or 

 (sound off).

 

Once select, press 

ENTER

 button to setup or automatically exit menu mode without any 

change after 30 seconds. To go back to the functions without any change press the 

MENU

 

button

 

 Blackout mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

 (blackout) or 

 (normal).

 

Once select, press 

ENTER

 button to setup or automatically exit menu mode without any 

change after 30 seconds. To go back to the functions without any change press the 

MENU

 

button 

 LED display 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select 

  (display on) or 

(display off) mode. Once select, press 

ENTER

 button to setup or exit menu mode 

without any change after 30 seconds. Back to the functions without any change press 

 

8- 

MENU

 button again. 

 Display Inverse 

Press 

MENU

 button until 

  is blinking on the display. Use 

DOWN

 and 

UP

 button to 

select 

 (normal) or 

 (inverse), press 

ENTER

 button to setup. Back to the 

functions without any change press 

MENU

 button. 

 Self-Test 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the unit will run the built-in programmer for self-test. To go back to the functions 

press the

 MENU

 button. 

 Temperature Test 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the temperature of the unit will show on the display. To go back to the functions 

press the

 MENU

 button. 

  Fixture Hours

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the display will show the number of working hours of the unit. To go back to the 

functions press the

 MENU

 button. 

 

Software version

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the display will show the version of software of the unit. To go back to the 

functions press the

 MENU

 button. 

 

Reset

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Press 

ENTER

 

button to reset the unit. 

 

5. How To Control The Unit   

You can operate the unit in three ways: 

 

1. By master/slave built-in preprogram function 

Summary of Contents for LED-275 D

Page 1: ...15 Innovation Quality Performance LED 275 D User Manual Please read the instructions carefully before use ...

Page 2: ...rk in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN 55103 1 1996 EN 55103 2 1996 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 Harmonized Standard EN 60598 2 17 1989 A2 1991 EN 60598 1 2008 EN62471 2008 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 3: ...ation of dirt on the fixture s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 2 TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How To Set The Fixture 5 How To Control The Fixture 6 DMX 512 Configuration 7 DMX ...

Page 4: ...mmer pack or power pack y Do not look directly at the LED light beam while the fixture is on y The housing must be replaced if they are visibly damaged y Do not touch any wire during operation as high voltage might be causing electric shock y Due to the magnifying type lens please keep the lens out of contact with direct sunlight Please read the instructions carefully which includes important info...

Page 5: ...sed 4 Direct sunlight can cause heat to build up inside of the unit which will seriously damage unit 2 Technical Specifications y It can be operated by DMX512 control or can be used as an individual unit without controller y It can be linked together as many as required in master slave mode and perform the great built in programmed lighting shows triggered by music y Please use a 3 pin XLR cable p...

Page 6: ...s power for the next unit 9 Mains input Connect to supply mains power 10 CA 9 connector Connect and control the unit via CA 9 11 CA 8 connector Connect and control the unit via CA 8 10 5 3 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the ...

Page 7: ...it to get contrast movement to each other even if you have two units only 5 2 Easy Controller by CA 8 CA 9 The easy remote control is used only in master slave mode By connecting to connector of the first unit you will find that the remote controller on the first unit will control all the other units for Stand by Function and Mode selection Blackout Blackout the unit Function 1 Synchronous Strobe ...

Page 8: ...utton up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select display on or display off mode Once select press ENTER button to setup or exit menu mode without any change after 30 seconds Back to the functions without any change press 8 MENU button again Display Inverse Press MENU button until is blinking on the display Use DOWN and U...