1. Safety Instruction 

 

 

 

WARNING 

 

 Please keep this User Manual for future consultation. If you sell the unit to another user, 

be sure that they also receive this instruction booklet. 

 Unpack and check carefully there is no transportation damage before using the unit. 

 Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit. 

 It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

 The unit is for indoor use only and use only in a dry location. 

 The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked. 

 Disconnect mains power before fuse replacement or servicing. 

 Replace fuse only with the same type. 

 Make sure there are not flammable materials close to the unit while operating as it is fire 

hazard. 

 Use safety cable when fixes this unit. 

 In the event of serious operating problem, stop using the unit immediately. Never try to 

repair the unit by yourself. Repair carried out by unskilled people can lead to damage or 

malfunction. Please contact the nearest authorized technical assistance center and 

always use the same type spare parts. 

 Do not touch any wire during operation as high voltage might be causing electric shock.

 

 

 

 

 

 

 

 

Please read the instruction carefully which including important 

information about the installation, operation and maintenance.

 

 

3- 

2. Technical Specification   

 It can be operated by DMX512 control or can be used as an individual unit without 

controller. 

 It can be linked together as many as required in master/slave mode, and perform the great 

built-in programmed lighting shows triggered by music. 

 Please use a 3 pin XLR cable/plug when connecting them together. 

 Fan cooled. 

 

Voltage:

 AC 100V-240V 50/60Hz

   

 Fuse:

 T2A 

 

Power:

 27 W

 

 

LED

  1X10W WHITE LED 

 

Dimension: 

210X210X179 mm 

 

Weight: 

1.8kg 

 

 

3. Installation   

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is 

firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure 

to which you are attaching the unit is secure and is able to support a weight of 10 times of 

the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the 

unit when installing the fixture.   

The equipment must be fixed by professionals. And it must be fixed at a place where is out 

of the touch of people and has no one pass by or under it. 

 

 

 

 

 

 

 

Summary of Contents for LED-256D-10W

Page 1: ...r Manual Professional Entertainment Technology 1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 Installation 4 How to Control the Unit 5 DMX 512 Configuration 6 DMX 512 Connection 7 Fixture Cleaning ...

Page 2: ...the nearest authorized technical assistance center and always use the same type spare parts Do not touch any wire during operation as high voltage might be causing electric shock Please read the instruction carefully which including important information about the installation operation and maintenance 3 2 Technical Specification It can be operated by DMX512 control or can be used as an individual...

Page 3: ...ement to the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show B Easy Controller by CA 8 The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit its DMX input plug is not used you will find that the remote control all the ...

Page 4: ... The cable can not be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables solder joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is connected to the unit 5 Each lighting unit needs to have an address set to receive the data s...

Page 5: ...s carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 9 EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 ...

Page 6: ...10 11 Innovation Quality Performance ...

Reviews: