ACME iMove 50SR User Manual Download Page 11

 

10E

blink. Use 

DOWN

 and 

UP

 button to adjust the home position of the Pan, Tilt, color, Gobo1, R-Gobo, Gobo2, 

Prism, R-Prism, or Focus. Once the position has been selected, press the 

ENTER

 button to setup, to go 

back to the functions without any change press the

 MENU

 button again. Hold and press the 

MENU

 button 

about one second or wait for one minute to exit the menu mode. 

 

  4. How To Control The Unit   

You can operate the unit in three ways: 

 

1. Master/slave built-in preprogram function 

  2. Easy controller 

3. Universal DMX controller 

No need to turn the unit off when you change the DMX address, as new DMX address setting will be effect 

at once. Every time you turn the unit on, it will show “LED-MS50” on the display and move all the motors to 

their ‘home’ position and you may hear some noises for about 20 seconds. After that the unit will be ready 

to receive DMX signal or run the built in programs. 

 

4.1 Master/Slave Built In Preprogrammed Function   

By linking the units in master/slave connection, the first unit will control the other units to give an automatic, 

sound activated, synchronized light show. This function is good when you want an instant show. You have 

to set the first unit in master mode 

Show Mode

 and select   

show 1

 or 

show 2 

or 

show 3

 or 

show 4

 mode. 

Its DMX input jack will have nothing plugged into it, and Its master LED will be constantly on and sound 

LED will flash to the music. The other units will have to set in 

slave mode

 and select 

Slave 1

 (normal) or 

Slave 2

 (2 light show) mode, Their DMX cables plugged into the DMX input jacks (daisy chain) and the 

slave led lights will constantly on. 

 
2-light show 

In 

slave mode

Slave 1 

means the unit works normally and 

Slave 2

 means 2-light show. In order to create 

a great light show, you can set 

Slave 2

 on the second unit to get contrast movement to each other, even if 

you have two units only. 

 

4.2 Easy Controller   

The easy remote control is used only in master/slave mode. By connecting to the 1/4” microphone jack of 

the first unit, you will find that the remote controller on the first unit will control all the other units in Stand by, 

and Mode selection. 

Stand By 

Blackout the unit 

Function 

1. Sync. Strobe 

2. Async strobe 

3. Sound Strobe 

Show 

1-4 

1. Press to select color 

2. Hold to select gobo 

Mode 

Sound (LED OFF) 

Show (LED 

Slow Blinking) 

LED ON 

 
4.3 DMX Controller   

By using a universal DMX controller to control the units, you will need to set DMX address from 1 to 512 so 

that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

DMX Address

 is showing on the display. Pressing 

ENTER

 button 

and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. Once the address 

has been selected, press the 

ENTER

 button to setup, to go back to the functions without any change press 

Summary of Contents for iMove 50SR

Page 1: ...iMove 50SR LED MS50A User Guide Professional Entertainment Technology ...

Page 2: ...1E TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 How To Set The Unit 4 How To Control The Unit 5 Troubleshooting 6 Fixture Cleaning ...

Page 3: ...rried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts y Do not touch any wire during operation as high voltage might be causing electric shock Warning y To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture y Do not open the unit within fiv...

Page 4: ...eel with 7 colors plus white y Pan 540 Tilt 270 y Automatic Pan Tilt position correction y Smooth 0 100 dimming and variable strobe speeds y Indexable replaceable 3 facet rotating prism y Auto focus y Beam angle 17 y LCD display for easy navigation and addressing y Perfect for disco club bar parties and Mobile DJs Voltage 100V 240V 50 60Hz Power consumption 130W Light source 1 50W White LED Dimens...

Page 5: ... Stand by Function and Mode function Mains input Connect to power supply DMX input output For DMX512 link use 3 5 pin XLR cable to link the unit together 3 2 Main Function To select any of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the r...

Page 6: ...5E ...

Page 7: ...he display Use DOWN and UP button to select the Yes Split Color mode or No normal mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Slave Mode Select Slave Mode press ENTER button to confirm present mode will blin...

Page 8: ...button about one second or wait for one minute to exit the menu mode Gobo1 Focus Select Gobo1 Focus press ENTER button to confirm present mode will blink on the display Use DOWN and UP button to select the 0 255 mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one sec...

Page 9: ... when the Fixture Time is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functions press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Firmware Version Press the MENU button up to when the Firmware version is blinking on the display Pressing ENTER ...

Page 10: ...ions will set to defaults setting to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Reset Press the MENU button up to when the Reset is blinking on the display Pressing ENTER button and all channels of the unit will return to their standard position 3 3 Home Position Adjust In the ...

Page 11: ... have nothing plugged into it and Its master LED will be constantly on and sound LED will flash to the music The other units will have to set in slave mode and select Slave 1 normal or Slave 2 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave led lights will constantly on 2 light show In slave mode Slave 1 means the unit works normally and Slave 2 means ...

Page 12: ...r one minute to exit the menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 15channels 1 16 31 46 16channels 1 17 33 49 4 4 DMX 512 Configuration 15 channel modes ...

Page 13: ...12E ...

Page 14: ...13E 16 channel modes ...

Page 15: ... 1 If you using a controller with 5 pins DMX output you need to use a 5 to 3 pin adapter cable 2 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the ...

Page 16: ...main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or...

Page 17: ... Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 ...