ACME IM-250 SP User Manual Download Page 1

User Guide

 

Please read these instructions carefully before use

 

 IM - 250 SP

Summary of Contents for IM-250 SP

Page 1: ...User Guide Please read these instructions carefully before use IM 250 SP ...

Page 2: ...ure 2 2 Inserting Exchanging rotating gobos 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjustment 4 4 Easy controller 5 How To Control The Unit 5 1 DMX Controller 5 2 DMX 512 Configuration 5 3 DMX 512 Connection 6 Troubleshooting 7 Maintenance and Cleaning ...

Page 3: ...type Make sure there are no flammable materials close to the unit while operating as it is fire hazard Please use safety chain while you fixing this unit Don t handle the unit by taking its head only but always by taking its base Maximum ambient temperature is ta 40 Don t operate it where the temperature is higher than this Unit surface temperature may reach up to 85 Don t touch the housing bare h...

Page 4: ...ged Do not look directly at the light while the bulb is on Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs by yourself In the unlikely event your unit may require service please contact your nearest dealer Installation The unit should be mounted via its mounting system as shown below on the bottom of the base Use clamps to fix the unit to ...

Page 5: ...ration and easy maintenance Gobo wheel Fixed gobo wheel 1 5 rotating interchangeable indexing gobos plus open Rotating gobo wheel 2 7 metal gobos plus open Magnetic Gobo wheels home positioning for easy calibration and easy maintenance Both rotate in both directions at different speeds creating shaking effect Effect Wheel Prism Rotating Prism Movement Pan 540 in 2 8 second Tilt 270 in 1 6 second P...

Page 6: ...nel 18 Tilt movement fine Channel 8 Gobo 1 Channel 19 Pan Tilt movement macro Channel 9 Gobo 1 Rotation Channel 20 Pan Tilt movement size Channel 10 Gobo 2 Channel 21 Iris effect Channel 11 No function Channel 22 Dimmer effect 16 Channels Channel 1 Pan Channel 9 Gobo 1 Rotation Channel 2 Tilt Channel 10 Gobo 2 Channel 3 Pan Tilt Speed Channel 11 No function Channel 4 Dimmer Channel 12 Prism Channe...

Page 7: ...os Open the cover by loosening the fastening screw at the sides of the cover If you wish to use other forms and patterns as the standard gobos or if the gobos are to be exchanged remove the fixation ring with an appropriate tool Remove the gobo and insert the new gobo Press the fixation ring together and insert it in the front of the gobo 1 Yoke 2 Front panel 3 Moving head 4 Handle 5 Base ...

Page 8: ...lamp with denatured alcohol and wipe it with a lint free cloth before installation 3 The lamp generates UV radiation Never operate the lamp without appropriate shielding 4 When burning the lamp operates at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its lifespan 5 Make sur...

Page 9: ...8A 4 How To Set The Unit 4 1 Control Panel MONITOR To show the various menus LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Blinking Sound Mode ...

Page 10: ... microphone jack to control the unit for Stand by Function and Mode function 4 2 Main Function To select any of the pre set functions press the ENTER button and turn jog wheel up to when the required one is shown on the monitor Select the function by ENTER button Use the jog wheel to change the mode Once the required mode has been selected press the ENTER button to setup or it will automatically r...

Page 11: ...r Pressing ENTER button and the display will blink Use jog wheel to change the DMX 512 address Once the address has been selected press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the previous functions without any change press the ESC button ...

Page 12: ... the Show Mode is shown on the monitor Pressing ENTER button and the display will blink Use jog wheel to change the Show Mode 1 4 Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the previous functions without any change press the ESC button Slave Mode Press the ENTER button and turn jog ...

Page 13: ... Inversion Press the ENTER button and turn jog wheel up to when the Tilt Inversion is shown on the monitor Pressing ENTER button and the display will blink Use jog wheel to select the Normal or Inversion mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the previous functions without ...

Page 14: ...cted press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the previous functions without any change press the ESC button Lamp On Power On Press the ENTER button and turn jog wheel up to when the Lamp On Power On is shown on the monitor Pressing ENTER button and the display will blink Use jog wheel to select the on or off mo...

Page 15: ... mode to adjust the home position when you want to adjust gobo and color home position you should be run Adjust Focus mode first the functions are shown below Adjust Focus Press the ENTER button for at least 12 seconds into offset mode turn jog wheel up to when the Adjust Focus is shown on the monitor Pressing ENTER button and the display will blink The unit will focus on tilt 135 and then the uni...

Page 16: ...econds Dimmer offset Press the ENTER button for at least 12 seconds into offset mode turn jog wheel up to when the Dimmer offset is shown on the monitor Pressing ENTER button and the display will blink Use jog wheel to adjust the dimmer home position Once the position has been selected press the ENTER button to setup or automatically return to the offset functions without any change press the ESC ...

Page 17: ...wheel to adjust the R gobo 1 home position Once the R gobo has been selected press the ENTER button to setup or automatically return to the offset functions without any change press the ESC button To go back to the main functions without any change after 10 seconds Gobo 2 offset Press the ENTER button for at least 12 seconds into offset mode turn jog wheel up to when the Gobo 2 offset is shown on ...

Page 18: ...ce the position has been selected press the ENTER button to setup or automatically return to the offset functions without any change press the ESC button To go back to the main functions without any change after 10 seconds Focus offset Press the ENTER button for at least 12 seconds into offset mode turn jog wheel up to when the Focus offset is shown on the monitor Pressing ENTER button and the dis...

Page 19: ...and move all the motors to their home position and you may hear some noises for about 20 seconds After that the unit will be ready to receive DMX signal 5 1 DMX Controller If you use a universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the ENTER button up to when the DMX address is shown on the monitor Pres...

Page 20: ...19A 5 2 DMX 512 Configuration ...

Page 21: ...20A ...

Page 22: ...21A ...

Page 23: ...le cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 5 Each lighting unit needs to have a DMX address to receive the data by the...

Page 24: ...ious one 4 Try to use another DMX controller 5 Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C No response to the sound 1 Make sure the unit is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone D One of the channels is not working well 1 The stepper motor might ...

Page 25: ...ot fix the belt too tight as it is easy to rupture 6 Plug all the connect wires back that upon belt 7 Screw all the screws A G If The tilt belt is broken 1 Turn off the main power 2 Unscrew all the screws A and open the right arm cover B 3 Change a new belt C Please adjust the tension of the belt properly Note do not fix the belt too tight as it is easy to rupture 4 Screw all the screws A ...

Page 26: ...igence of maintenance would cause malfunction of the fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth u...

Page 27: ...omagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN 60598 1 2004 IEC 60598 1 2003 corrigendum 2004 Part 1 General requirements and test Following the provisions of the low voltage directive 73 23 EEC and 93 68 EEC Innovation Quality Performance ...

Reviews: