1. Safety Instructions   

 

 

WARNING   

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that 

they also receive this instruction manual. 

Important: 

Damages caused by the disregard of this user manual are not subject to warranty. The dealer 

will not accept liability for any resulting defects or problems

 

Unpack and check carefully that there is no transportation damage before using the unit. 

 

The unit is for indoor use only. Use only in a dry location. 

 

DO install and operate by qualified operator. 

 

DO NOT allow children to operate the fixture. 

 

Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 

surfaces.   

 

Be sure that no ventilation slots are blocked, otherwise the unit will be overheated. 

 

Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature TA: 40

maximum ambient temperature TA: 0

.   

 

DO NOT connect the device to any dimmer pack. 

 

During initial start-up some smoke or smell may arise. This is a normal process and does not 

necessarily mean that the device is defective, and it will decrease gradually within 15 minutes. 

 

Make sure there are no flammable materials close to the unit while operating to avoid fire hazard. 

 

Examine the power wires carefully; replace them immediately if there is any damage. 

 

Unit’s surface temperature may reach up to 56

. DO NOT touch the housing bare-handed during 

its operation, and allow about 15 minutes for cooling the unit down before replacing bulb or 

maintenance as it could be very hot. 

 

Avoid any inflammable liquids, water or metal objects entering the unit. Once it happens, cut off 

Please read the instruction carefully which includes important information about 

the installation, usage and maintenance. 

 

2A 

Summary of Contents for FARANDOLE AM-BAR

Page 1: ......

Page 2: ...ns 3 3 Description 5 3 1 Control Panel 5 4 How To Set The Unit 5 4 1 Main Function 5 4 2 Error Information 9 5 Control By Universal DMX Controller 10 5 1 Connection 10 5 2 Address Setting 11 5 3 DMX 5...

Page 3: ...he voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperat...

Page 4: ...n the unit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest a...

Page 5: ...in out Protection Rating IP20 Features Efficient LED lens uniform color mixing which makes the light effect better 0 100 smooth dimming Adjustable electronic strobe effect Suitable for fixed installat...

Page 6: ...XLR plug cable to link the units together 4 How To Set The Unit 4 1 Main Function Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is show...

Page 7: ...ut any change after 1 minute automatically Back to the previous functions without any change press the MENU button Channel Mode Select the press the ENTER button Use the DOWN and UP button to select t...

Page 8: ...urve 2 Dimmer curve 3 Dimmer curve 4 Optically Linear Square Law Inverse Square Law S Curve Mode 1 Optically Linear The increase in light intensity appears to be linear as DMX value is increased Mode...

Page 9: ...button Manual Test Select the press the ENTER button Use the DOWN and UP button to select or Once selected press the ENTER button to setup use the DOWN and UP button to adjust the value from 0 to 255...

Page 10: ...n temperature check board is damaged Memory Initial Fail It appears when the memory IC is damaged CPU B Error CPU C Error CPU D Error They appear when board P C or some wires are damaged Pan Reset Err...

Page 11: ...The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by th...

Page 12: ...idle one minute to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 6...

Page 13: ...39 140 181 182 189 190 231 232 239 240 247 248 255 Strobe Close Open Strobe Slow Fast Open Fast Close Slow Open Open Fast Open Slow Close Open Random Strobe Open 6 000 255 Dimmer 7 000 255 Dimmer Fine...

Page 14: ...100 139 140 179 180 219 220 255 CTO NO FUNCTION 10000K 7200K 5600K 4200K 3200K 2700K 6 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions fo...

Page 15: ...tepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 7 Cleaning The cleaning of internal and external optical lenses an...

Page 16: ...the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN 60598 2 17 19...