background image

 

7- 

 

 

12-

 (random show) or 

  (show 1) or… or 

  (show 12) mode. Its DMX input 

jack will have nothing plugged into it, and Its master LED will be constantly on and sound 

LED will flash to the music. The other units will have to set in slave mode 

 and select 

 (normal) or 

  (2 light show) mode, Their DMX cables plugged into the DMX 

input jacks (daisy chain) and the slave led lights will constantly on. 

2-light show 

In 

 (slave  mode), 

 means the unit works normally and 

 means 

2-light show. In order to create a great light show, you can set 

  on the second unit to 

get contrast movement to each other, even if you have two units only. 

 

4.2 Easy Controller   

The easy remote control is used only in master/slave mode. By connecting 

to the 1/4” microphone jack of the first unit, you will find that the remote 

control on the first unit will control all the other units functions press the 

MENU button again. 

 

 

4.3 DMX Controller   

By using a universal DMX controller to control the units, you have to set DMX address from 

1 to 512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press and keep 

ENTER

 button pressed up to when 

the display stops blinking or storing automatically 8 seconds later. To go back to the 

functions without any change press the

 MENU

 button again. If you use please refer to the 

following diagram to address your DMX512 channel for the first 4 units

 

 

Summary of Contents for Dragon Scan 50 LED-SC50B

Page 1: ...19 Innovation Quality Performance DRAGON SCAN 50 LED SC50B User Guide Professional Entertainment Technology Широкий ассортимент оборудования ACME на www maxlight ru ...

Page 2: ...ordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 3: ...operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 2 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 How To Set The Unit 4 H...

Page 4: ...ectric shock Warning y To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture y Do not open the unit within five minutes after switching off Please read carefully the instruction which includes important information about the installation usage and maintenance 16 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 Pin 5 Not used 5 Upd...

Page 5: ...ultraviolet filter must be replaced if they are visibly damaged Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact your nearest dealer Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibra...

Page 6: ...ve Mode SOUND Flashing Sound activation Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Only for remote control Connecting with CA 8 CA 9 CA 9RTX to control the unit for Stand by Function and Mode function Mains input Connect to power supply DMX input output For DMX512 l...

Page 7: ...lect the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode The main functions are showing below ...

Page 8: ...r slave mode By connecting to the 1 4 microphone jack of the first unit you will find that the remote control on the first unit will control all the other units functions press the MENU button again 4 3 DMX Controller By using a universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when t...

Page 9: ...er mode and select 8 DMX 512 Address Setting Press the MENU button to show on the display Press the ENTER button and the display will blink Use the DOWN and UP buttons to change the DMX512 address Once the address has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for o...

Page 10: ...it the menu mode Display Inversion It is good for you to install the unit on the floor or under ceiling Press the MENU button to show on the display Press the ENTER button to change to the mode 10 display normal It will automatically store after 8 seconds Or press the ENTER button again return to the mode display inversion To go back to the functions press the MENU button Hold and press the MENU b...