ACME DAZZLED COLORLED-430 User Manual Download Page 3

 

 

4B 

2. Technical Specification   

y

  It can be operated by DMX512 control or can be used as an individual unit without 

controller. 

y

  It can be linked together as many as required in master/slave mode, and perform the 

great built-in programmed lighting shows triggered by music. 

y

  Please use a 3 pin XLR cable/plug when connecting them together. 

y

 Fan 

cooled. 

y

 4Channels: 

Channel 1 = Red 

Channel 2 = Green 

Channel 3 = Blue 

Channel 4 = Dimmer/Strobe 

y

 Voltage: 

AC 

100V-240V 

50/60Hz 

y

  Power: 7 W 

y

  Light Source: 1

×

3W RGB LED 

y

 Dimension: 

222x300x124mm 

y

  Weight: 1.3 kg 

 

 

3. Installation   

You can install the unit on the truss or ceiling, Use clamps to fix the unit to truss. Always 

ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always 

ensure that the structure to which you are attaching the unit is secure and is able to support 

a weight of 10 kg

 

for each unit. 

 

 

4. How To Control The Unit   

Three ways to operation: 

A. Master/Slave operation 

B. Easy controller CA-8 

C. Universal DMX controller 

 

 

5B

A. Master/Slave operation 

The unit can be linked together in daisy chain as many as you need in master/slave mode to 

perform the great built-in pre-programmed lighting shows triggered by music. 

In Master/Slave mode, refer to the DMX settings below:   

Master unit: DIP switch #10 = ON 

Slave units: All DIP switches OFF 

 

2-light show: 

Turn on the DIP switch #10 for the first unit and DIP switches #1 and #3 for the other, then 

you can enjoy different lighting shows of the two units. 

 

B. Easy Controller (by CA-8) 

The easy remote control is used only in master/slave mode. By connecting to the 1/4” 

microphone jack of the first unit (its DMX input plug is not used), you will find that the remote 

control all the first unit will control all the other units for Stand by, Function and Mode. Built-in 

lighting shows triggered by Easy Controller: 

 

Stand by 

Blackout the unit 

Function 

1. Synchronous Strobe 

2. Four light Strobe 

3. Sound Strobe 

Chase 

Mode 

Strobe (LED OFF) 

Latch (LED ON) 

 

C. Universal DMX controller

 

When using a universal DMX controller to control the chain of units, you have to set DMX 

address by Dip switches from 1 to 9 to make sure all the units will receive its DMX signal.   

Please refer to the following diagram to know how to address your DMX 512 system in the 

binary code. 

DMX 512 Address Chart:

   

Dip-switches

#  1

#  2

#  3

#  4

#  5

#  6

#  7

#  8

#  9 

#10 

Value 1 

16

32

64

128

256 

4-light 

show 

 

 Examples: 

Channel 1

dip / on: #1 (=1) 

Summary of Contents for DAZZLED COLORLED-430

Page 1: ...DAZZLED COLOR LED 430 User Manual Professional Entertainment Technology 1B ...

Page 2: ...n a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect mains power before fuse replacement or servicing Replace fuse only with the same type Make sure there are not flammable materials close to the unit while operating as it is fire hazard In the event of serious operating problem stop using the unit immediately Never tr...

Page 3: ... in master slave mode to perform the great built in pre programmed lighting shows triggered by music In Master Slave mode refer to the DMX settings below Master unit DIP switch 10 ON Slave units All DIP switches OFF 2 light show Turn on the DIP switch 10 for the first unit and DIP switches 1 and 3 for the other then you can enjoy different lighting shows of the two units B Easy Controller by CA 8 ...

Page 4: ...te or damaged cables solder joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is connected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of...

Page 5: ...irt on the unit s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 9B ...

Page 6: ...rovision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements 11B Innovation Quality Performance ...