ACME CW-108 User Manual Download Page 3

 
 

 

17B 

E. One of the channels is not working well 

1.

 

The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.

 

The motor’s drive IC on the PCB might be out of condition 

 

 8. Fixture Cleaning  

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 

accumulation of dirt on the unit’s optics. 

y

 

Clean with soft cloth using normal glass cleaning fluid. 

y

 

Always dry the parts carefully. 

y

 

Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

2B 

  1. Safety Instructions   

 

 

WARNING 

 

 

y

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

y

 

Please unpack and check carefully there is no transportation damage before using the unit. 

y

 

Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

y

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

 

The unit is for indoor use only. Use only in a dry location. 

y

 

The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

y

 

Please disconnect main power before replacement or servicing.   

y

 

Please make sure there are no flammable materials close to the unit while operating as it is 

fire hazard.   

y

 

Please use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, 

but always by taking its base.     

y

 

Maximum ambient temperature is Ta: 40

. DO NOT operate it where the temperature is 

higher than this. 

y

 

Unit surface temperature may reach up to 85

. DO NOT touch the housing bare-hand 

during its operation. Turn off the power and allow about 15 minutes for the unit to cool 

down before replacing or serving. 

Please read the instruction carefully, it includes important 
information about the installation, usage and maintenance. 

Summary of Contents for CW-108

Page 1: ...Innovation Quality Performance CW 108 User Manual Please read the manual carefully before using...

Page 2: ...oting 16 8 Fixture Cleaning 17 Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of...

Page 3: ...before using the unit y Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit y It s important to ground the yellow green conductor to earth i...

Page 4: ...of the touch of people and has no one pass by or under it For 230V 50Hz power supply maximum fixtures that can be connected on one power cable is 8 For 120V 60Hz power supply maximum fixtures that can...

Page 5: ...is disconnected 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX 512 sy...

Page 6: ...nctions 5 ENTER To confirm the selected functions LED 6 DMX On DMX input present 7 MASTER On Master Mode 8 SLAVE On Slave Mode 9 SOUND Flashing Sound activation 10 Microphone Receive the Sound to cont...

Page 7: ...in Function To select any functions press the MENU button until the required one is shown on the display Select the function by the ENTER button and the display will blink Use the DOWN and UP button t...

Page 8: ...nits for Stand by Function and Mode selection Blackout To blackout all the fixture Function Strobe 1 Synchronous strobe 2 Two light strobe 3 Sound strobe Select Chase Select color Select Fade Speed Fa...

Page 9: ...e ENTER button and the display will blink Use the DOWN and UP button to change the DMX 512 address Once the address has been selected press the ENTER button to setup or automatically exit menu mode wi...

Page 10: ...tup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button 10B LED display Select the press the ENTER button and the d...