4.2.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select
, press the ENTER button to confirm,
the present address will blinking the display, use the UP/DOWN button to adjust the address from
001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let
the unit idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
4 channels
1
5
9
13
5 channels
1
6
11
16
7 channels
1
8
15
22
4.2.3 DMX512 Configuration
Please control the fixture by referring to the configurations below
Attentions:
1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
2. For the channel Function, keep the value for about 3 seconds, then the corresponding
function will take into effect.
14E