ACME CM-70Z User Manual Download Page 18

 
 

 

17A

3.

 

If

 

you

 

have

 

intermittent

 

DMX

 

signal

 

problems,

 

check

 

the

 

pins

 

on

 

connectors

 

or

 

on

 

PCB

 

of

 

the

 

unit

 

or

 

the

 

previous

 

one.

 

4.

 

Try

 

to

 

use

 

another

 

DMX

 

controller.

     

5.

 

Check

 

if

 

the

 

DMX

 

cables

 

run

 

near

 

or

 

run

 

alongside

 

to

 

high

 

voltage

 

cables

 

that

 

may

 

cause

 

damage

 

or

 

interference

 

to

 

DMX

 

interface

 

circuit.

   

C.

 

Some

 

units

 

don’t

 

respond

 

to

 

the

 

easy

 

controller

   

1.

 

You

 

may

 

have

 

a

 

break

 

in

 

the

 

DMX

 

cabling.

 

Check

 

the

 

LED

 

for

 

the

 

response

 

of

 

the

 

master/

 

slave

 

mode

 

signal.

 

2.

 

Wrong

 

DMX

 

address

 

in

 

the

 

unit.

 

Set

 

the

 

proper

 

address.

 

D.

 

No

 

response

 

to

 

the

 

sound

 

1.

 

Make

 

sure

 

the

 

unit

 

does

 

not

 

receive

 

DMX

 

signal.

 

2.

 

Check

 

microphone

 

to

 

see

 

if

 

it

 

is

 

good

 

by

 

tapping

 

the

 

microphone

 

3.

 

Make

 

sure

 

the

 

fixture

 

is

 

not

 

set

 

into

 

Blackout

 

mode

 

E.

 

One

 

of

 

the

 

channels

 

is

 

not

 

working

 

well

 

1.

 

The

 

stepper

 

motor

 

might

 

be

 

damaged

 

or

 

the

 

cable

 

connected

 

to

 

the

 

PCB

 

is

 

broken.

 

2.

 

The

 

motor’s

 

drive

 

IC

 

on

 

the

 

PCB

 

might

 

be

 

out

 

of

 

condition.

 

 

 

7.

 

Fixture

 

Cleaning

   

The

 

cleaning

 

must

 

be

 

carried

 

out

 

periodically

 

to

 

optimize

 

light

 

output.

 

Cleaning

 

frequency

 

depends

 

on

 

the

 

environment

 

in

 

which

 

the

 

fixture

 

operates:

 

damp,

 

smoky

 

or

 

particularly

 

dirty

 

surrounding

 

can

 

cause

 

greater

 

accumulation

 

of

 

dirt

 

on

 

the

 

unit’s

 

optics.

 

y

 

Clean

 

with

 

soft

 

cloth

 

using

 

normal

 

glass

 

cleaning

 

fluid.

 

y

 

Always

 

dry

 

the

 

parts

 

carefully.

 

y

 

Clean

 

the

 

external

 

optics

 

at

 

least

 

every

 

30

 

days.

 

 

 

 

 

 

 

 

Summary of Contents for CM-70Z

Page 1: ...CM 70Z User Manual Please read the instruction carefully before use ...

Page 2: ...The Unit 4 3 1 Control Panel 4 3 2 Main Function 5 3 3 Home Position Adjustment 11 4 How to Control the Unit 12 4 1 Master Slave Built In Preprogrammed Function 12 4 2 DMX Controller 12 4 3 DMX 512 Configuration 13 5 DMX512 Connection 15 6 Troubleshooting 16 7 Fixture Cleaning 17 ...

Page 3: ...le materials close to the unit while operating as it is fire hazard y Please use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base y Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this y Unit surface temperature may reach up to 75 DO NOT touch the housing bare hand during its operation Turn of...

Page 4: ...hat the unit is firmly fixed to avoid vibration and slipping while operating Make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed in a pl...

Page 5: ...Cable Daisy Chains 8 Fixtures Max 230V 50Hz 4 Fixtures Max 120V 60Hz Light Source 7 x 10W OSRAM OSTAR RGBW LED Beam angle 10 60 Weight 6 2Kgs Dimension 267 x 163 x 321mm 3 How To Set The Unit 3 1 Control Panel 1 Function Display To show the various menus and the selected functions ...

Page 6: ... the optional CA 8 to control the unit 8 DMX OUT DMX512 link use 3 pin XLR cable to link the next unit and output DMX signal 9 DMX IN DMX512 link use 3 pin XLR cable to link the unit and the DMX controller 3 2 Main Function To select any of the given functions press the MENU button up to the required selection as shown on the display Select the function by the ENTER button and the display will bli...

Page 7: ...6A ...

Page 8: ...in Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Slave Mode To select Slave Mode press the ENTER button to show the SLAVE MODE on the display Use the DOWN UP button to select the Slave 1 or Slave 2 mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press a...

Page 9: ...lected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Sound Sense To select Sound Sense press the ENTER button to show the SOUND SENSE on the display Use the DOWN UP button to adjust the sensitivity level the sensitivity level can be adjusted ...

Page 10: ...U button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Tilt Inverse To select Tilt Inverse press the ENTER button to show the TILT INVERSE on the display Use the DOWN UP button to select the Yes tilt inversion or No normal mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change pres...

Page 11: ...etup go back to the functions without any change press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Auto Test To select Auto Test press the ENTER button and the unit will run self test by built in program To go back to the functions press the MENU button again Press and hold the MENU button about one second or wait for one m...

Page 12: ... hold the MENU button for about one second or wait for one minute to exit the menu mode Reset To select Reset press the ENTER button to show the RESET on the display and all channels of the unit will return to their standard position Press and hold the MENU button for about one second or wait for one minute to exit the menu mode 3 3 Home Position Adjustment In the main functions hold the ENTER but...

Page 13: ...ack will have nothing plugged into it and its master LED will be constantly on and sound LED will flash to the music The other units will have to set in slave mode and select Slave 1 normal or Slave 2 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave led lights will constantly on 2 light show In slave mode Slave 1 means the unit works normally and Slave ...

Page 14: ...00 255 TILT FINE 5 000 255 PAN TILT SPEED fast slow 6 000 009 010 014 015 255 SPECIAL FUNCTIONS No function Reset No function 7 000 255 DIMMER 0 100 8 000 019 020 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 SHUTTER Closed Open Strobe 1 fast slow Open Strobe 2 opening pulse fast slow Open Strobe 3 closing pulse fast slow Open S...

Page 15: ...4 145 149 150 154 155 159 160 164 COLOR MACRO Open LEE 790 Moroccan Pink LEE 157 Pink LEE 332 Special Rose Pink LEE 328 Follies Pink LEE 345 Fuchsia Pink LEE 194 Surprise Pink LEE 181 Congo Blue LEE 071 Tokyo Blue LEE 120 Deep Blue LEE 079 Just Blue LEE 132 Medium Blue LEE 200 Double CT Blue LEE 161 State Blue LEE 201 Full CT Blue LEE 202 Half CT Blue LEE 117 Steel Blue LEE 353 Lighter Blue LEE 11...

Page 16: ...4 Flame Red Open Color wheel rotation effect Clockwise fast slow Stop this will stop wherever the color is at the time Counter clockwise slow fast Open Random color Fast Medium Slow Open 14 000 255 ZOOM wide narrow 5 DMX512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels ...

Page 17: ...ds to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX 512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 Pi...

Page 18: ... unit does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone 3 Make sure the fixture is not set into Blackout mode E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 7 Fixture Cleaning The cleaning must be carried out periodicall...

Page 19: ...h the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 20: ...Innovation Quality Performance ...