1. General notes

This manual provides you with an overview of the necessary steps for commissioning and opera-

ting the computer system. Please read them even if you are familiar with the operation of compu-

ter systems.

We will use the term “unit” to designate the OR-PC

®

 xx model manufactured by ACL GmbH. xx is 

used to identify the display size between 09 and 55 inches.

2. Classification and intended use

The unit is designed for documenting data such as patient information inside and outside of 

operating theaters, intensive-care wards and similar areas of application. It is supporting the local 

software environment and it may be part of the IT network.

Following Section 6 of IEC 60601-1:2012 the unit is classified as below:

6.2  protective class I unit

6.3  see IP label on your unit, depending on your model IP20 or IP31

An optional IP65 upgrade is available on request for all models.

6.4  This unit is not intended for sterilization.

6.5  It is not intended for operating in an environment with enriched oxygen.

6.6  This unit is suited for permanent operation.

The unit is considered as professional ME-Equip according to IEC 60601-1-2:2014, paragraph 3.23.

It not is allowed to simultaneously touch the patient and pins of signal input/output components 

when connecting the unit to other devices.

The unit can be used within the patient environment.

This unit is not suited to be used in direct contact with the patient.

The patient is not supposed to operate or maintain the unit.

It is not allowed to use this unit in private households.

The unit is not protected against explosions.

Only qualified expert personnel, which is familiar with the unit and its manual, may install, operate 

and maintain the unit.

There is no information required for activities that should avoid damage to humans, animals or 

environment.

Third-party equipment may be connected in consideration of the restrictions in 

Section 3.1

.

3. Installation and commissioning

The unit was cleaned before leaving our production facilities. However, the units are neither sterile 

nor disinfected on arrival due to transport conditions and packing. Advices for initial cleaning can 

be found at  

Section 5.1

.

Make sure that the unit and its accessories are complete according to the attached delivery note.

Keep the original transport box and packaging for the event that it might have to be transported 

back (this does not apply to units with on-site service).

The integrated VESA-100 interface on the rear can be used to flexibly attach the unit to mounting 

solutions and other devices. Various manufacturers offer a whole series of adapters or installation 

solutions for this. We would be pleased to offer customized installation solutions on your request.

The unit may only be operated in an upright position (do not operate it in any direction at an 

inclination of more than 30° from the norm). The only units that may be operated with a screen 

rotated at 90° (portrait mode) are those specially designated as such (i.e., portrait models). It is not 

allowed to operate it in impermissible positions (reversed and lying on its head, back or display) 

because this may damage the unit.

Only use the screws supplied and always use all fastening screws (

orange

) for correct and save 

assembly.

Summary of Contents for OR-PC Series

Page 1: ...ALWAYS A STEP AHEAD Manual OR PC series...

Page 2: ...e manufacturing process is environmentally friendly as our production is powered by our own solar energy on the way to a climate neutral manufacturing process If there is any complaint about this prod...

Page 3: ...use this unit in private households The unit is not protected against explosions Only qualified expert personnel which is familiar with the unit and its manual may install operate and maintain the un...

Page 4: ...intended to be used for medical purpose i e unit is controlling infusion pumps or applied parts are connected Validity of any assured properties nor conformity to standards for the unit cannot be expa...

Page 5: ...er not listed above the recommended separation distance d in meters m can be determined using the equation applicable to the frequency of the transmitter where 3 2 Device environment safety and handli...

Page 6: ...ion IEC 60417 5021 fuse specification EN 60617 2 07 21 01 manufacturer ISO 15223 1 date of manufacturing ISO 15223 1 WEEE 2002 96 EG Annex IV barcode scanner RFID scanner P is the maximum output power...

Page 7: ...he unit is cleaned and disinfected with an appropriate cleanser every time it is sent back for repair If you are not able to do so mark the unit as contaminated and use safety foil to seal it twice To...

Page 8: ...nces short sporadic signal loss key panel triggered without user interaction The unit does not have an alarm system 5 4 In house repairs Diligent testing of the unit is guaranteed by the manufacturer...

Page 9: ...uitable materials for your device at short notice at cost price Improper packaging may result in damage to individual components Therefore ensure careful handling during transport and loading operatio...

Page 10: ...o DE 191 570 067 Trademarks Trademarks used are the property of their respective owners All rights reserved in particular for patents utility models and design patents deli very possibilities and tech...

Page 11: ...www acl de ALWAYS A STEP AHEAD...

Reviews: