background image

Made in
Germany

www.orpc.com

User Manual

Revision 4.2c2 (October 2019)

Translated Version:  English
Original version: 

German

ACL Medical Display

Series OR-MD®

Summary of Contents for OR-MD Series

Page 1: ...Made in Germany www orpc com User Manual Revision 4 2c2 October 2019 Translated Version English Original version German ACL Medical Display Series OR MD ...

Page 2: ...s for Care and Hygiene 5 2 5 3 11 11 Maintenance Intervals and Wear Parts Faulty Signals and Alarm Signals 5 4 5 5 12 13 Repairs Instructions for Transporting ACL Units 5 6 14 Environmentally Correct Disposal 6 15 Getting in Contact with the Manufacturer 7 15 Imprint 8 8 1 16 16 Warranty and Guarantee The Warranty 8 2 8 3 17 18 The Guarantee Scope of and Performing Services 8 4 8 5 18 19 The Servi...

Page 3: ...ical inaccuracies and typographical errors although its information is updated and adapted regularly We have put great efforts into providing you with correct and generally understandable informa tion although the manufacturer cannot assume any liability for any errors that might be here We reserve ourselves the right to make changes in or improve the products described and we are particularly grat...

Page 4: ...n 6 6 This unit is suited for permanent operation Third party equipment may be connected in consideration of the restrictions in section 3 1 The unit is considered as professional ME Equip according to DIN EN 60601 1 2 2016 paragraph 3 23 It not is allowed to simultaneously touch the patient and pins of signal input output components when connecting the unit to other devices The unit can be used w...

Page 5: ...the backside of the unit to flexibly and independently integrate the it into a wide variety of environments and applications Various manufacturers offer a whole series of adapters or installation solutions for this If you want we can offer you customized installation solutions Only use the screws supplied and always use all fastening screws orange for correct and save assembly The unit may only be o...

Page 6: ...m trips over them or can put heavy objects on them to prevent the hazard of injury and damage to the unit Make sure that there is a fixed location and or stable suspension The industrial protection class of your unit can be upgraded up to IP65 If you have chosen this optional upgrade one of the central elements of the IP65 sealing is the cover for the connector interface on the lower side of the u...

Page 7: ... an electrical connection with other devices or when operating the unit at a mobile multiple outlet compliance to the latest version of DIN EN 60601 1 has to be ensured To maintain conformity in this case so called decoupled connectors are available optionally Data can be transferred through this galvanic isolation without any direct electrical contact From the electrical point of view the connect...

Page 8: ...u do not use the unit for a longer period of time this does not have any impact on the running programs or functions of the unit A LED in the operating panel indicates the fact that the display is deactivated Alternatively a screensaver could be used Protect the unit from strong magnetic fields like the field close to a MRI Protect the unit from exposure to strong electromagnetic radiation Operati...

Page 9: ...RF emissions are very low and are not likely to cause any interference in nearby electronic equipment Class B Class D The unit is suitable for other use than in domestic establishments The unit is suitable to be directly connected to the public low voltage power supply network RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000 3 2 For transmitters rated at a maximum output po...

Page 10: ...ion manufacturer date of manufacturing WEEE barcode scanner IEC 60417 5031 IEC 60417 5032 IEC 60417 5019 IEC 60417 5021 ISO 15223 1 ISO 15223 1 2002 96 EG Annex IV RFID scanner IEC 60417 5007 and IEC 60417 5008 and do not touch none MEDICAL GENERAL MEDICAL EQUIPMENT AS TO ELECTRICAL SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH ANSI AAMI ES60601 1 A1 2012 C1 2009 R 2012 und A2 2010 R 2...

Page 11: ...isinfection you need to hold your finger on a key for at least 0 3 4 1 Operating Panel The unit operates with the operating panel on the front The key and LED layout varies according to the equipment you chose for your unit The following key functions can be included example figure OR MD key panel LED displays kein Signal ready to operate red green on flashing unit operating off unit in standby not...

Page 12: ...acetone citric acid cleaning liquids basing on crude oil like petroleum turpentine or oil Using cleaning pads rough sponges and cloths might damage surfaces and sealing material Please make sure that the unit is cleaned and disinfected with an appropriate cleanser every time it is sent back for repair If you are not able to do so mark the unit as contaminated and use safety foil to seal it twice T...

Page 13: ...nit in this case because operating the unit with damaged components can cause further damage Disconnect the unit from the network immediately in the following cases and get in contact with the manufacturer or authorized service technician unusual odor or smoke a high level of heat escaping from the unit damage to the power cable or plug faulty unit functioning although you followed the operating i...

Page 14: ...facturer at the address in section 6 for training and advisory as well as the service manual Incorrect repairs are a safety risk You should not apply your own setting or adjusting methods if they do not comply with the unit s specifications or use components not supplied or approved by ACL GmbH because that might damage the unit Finally it is not allowed to make any changes or modifications in the...

Page 15: ... model name on the type plate OR MD 15 to OR MD 24 OR MD 27 and OR MD 32 Remove all cables mounting systems and other accessories Place the unit between the swing foils Press both swing foils onto each other The unit shall not have any space to move between the foils Place the accessory box on the upper swing foil Use a knife to cut down all four carton corners until the swing foils have no room l...

Page 16: ...ss given in Section 6 or with an authorized disposal company for returning your old units We would be glad to advise you as to the options for disposing of your ACL unit Return can be refused for old equipment that constitutes a risk to human health or safety due to contamination during usage The Directive of the European Union states that electrical or electronic units designated with one of the ...

Page 17: ...erve ourselves the right to make modifications in terms of technical progress All copyrights shall be reserved to ACL GmbH All rights reserved Editor ACL GmbH Apelsteinallee 5 04416 Markkleeberg Germany www orpc com Amtsgericht Leipzig HRB 13844 VAT ID DE 191 570 067 Trademarks The trademarks used are the property of each of their owners All rights reserved in particular for patents utility models...

Page 18: ...from the guarantee than those described here Regardless of this there may be guarantees of ACL sales partners or other third parties along with this manufacturer s guarantee that you can also assert against them 8 1 The Warranty The warranty period is 24 months and the warranty commences on the day that a customer of ACL purchases the product for the first time the date of the original invoice or ...

Page 19: ...rantee from another manufacturer for some components Please do not hesitate to get in contact with the address specified in Section 6 if you have any questions guarantee with on site service The customer reports a defective unit to ACL GmbH by email or phone If ACL GmbH cannot correct the malfunction on the phone an ACL service partner will repair the fault at the customer s location Please do not...

Page 20: ...data or software The Service is done by repair or replacement at ACL GmbH s choice within the conditions above Defective components are replaced with new or as new components in the event of material and or processing faults or the entire product may be replaced with the same or a functionally equivalent product In any event the value of the service shall be restricted to the value of the faulty p...

Page 21: ...ticle code of the product the date and name of the vendor you have bought the unit from a brief description of the problem an address we should send the unit to once it is repaired optional a process number that we will use in all related documents 3 Fax Please contact us at the fax number from section 6 Please ensure that the information above are part of the fax if possible Afterwards you will g...

Page 22: ...nts or be their consequence 8 6 Other Services In this framework we would like to point out the option of purchasing an extension to the scope of the guarantee customer service for your ACL products in accordance with your personal needs You can get more detailed information on this directly from ACL or our sales partners ACL guarantee extensions shall be subject to the conditions described in thi...

Page 23: ...www orpc com ...

Page 24: ...any Phone 49 341 230 78 0 Fax 49 341 230 78 99 Email info acl de Website www orpc com No reproducing in any form of this manual in whole or in part may be made without written authorization from ACL GmbH All rights reserved 10 2019 Subject to change without notice ...

Reviews: