Acksys SWA A10 Quick Installation Manual Download Page 6

Documentation ref DTUS075 rev A0 06/18/20 

-6- 

 

The DIAG led stay off for around 40 seconds, until the device is fully ready to 

use. Then the DIAG led turns blue. 

 

 

Step 3 – ETHERNET CONNECTION 

Connect the Ethernet cable (if it not connected in case of PoE or PPoE). 

 

 

DEVICE CONFIGURATION 

 

FACTORY SETTINGS: 

 

  IP address: 192.168.1.253 

  Radio Interface disable, preset for access point mode 

  SSID: acksys (broadcast) 

  No security (no WEP, no WAP, no WAP2, no MAC filter) 

  802.11n or ac mode, 5GHz band, auto-channel 

  WEB interface for device configuration:   

IP address: 192.168.1.253 

User name: root 

Password: no password set as factory setting  

 

Step 1 

Verify that the IP address factory setting is compatible with your network, if 

the IP address is not suitable for your network use Windows application 

WaveManager

 (available on web sit

www.acksys.fr

). 

 

 

 

After the WaveManager installation run the application, select the 

EmbedAir1000 device then click to “Setup”: now you can configure the IP 

address or you can activate the DHCP client. 

 

 

Step 2 

Using your web browser open the WEB interface (IP address: 192.168.1.253) 

and select the “SETUP” tab: 

 

 

 

 

 

Summary of Contents for SWA A10

Page 1: ...read the full manual WaveOS user guide You will need a PC equipped with Ethernet access to install the WaveManager software a web browser IE compatible an android smartphone if you want to install the...

Page 2: ...fety characteristic of the device after maintenance 9 If the equipment is likely to come in to contact with aggressive substances it is responsibility of the user to take suitable precautions that pre...

Page 3: ...ring diagram present into the Annex to Installation Operation Manual Reassemble screw cover and lock it by means of the screw or anti rotation kit WARNING Before closing the enclosure check that threa...

Page 4: ...A11 A12 POWER SUPPLY Screw terminals Supply voltage 18 60 VDC RJ45 connector PPoE 24 VDC or PoE 48 VDC Max Power Consumption 8W for A10 14W for A11 and A12 PPoE Passive Power over Ethernet operating...

Page 5: ...edance and with operating frequency in according to technical data listed into the above paragraph RF information The device must be set according to limitation listed at paragraph MAXIMUM PERMITTED R...

Page 6: ...n or ac mode 5GHz band auto channel WEB interface for device configuration IP address 192 168 1 253 User name root Password no password set as factory setting Step 1 Verify that the IP address factory...

Page 7: ...try selector is located in the global parameters near the bottom of the page You can select radio interface to set up its WiFi parameters you can also change IP configuration and services In function...

Page 8: ...t come up Make sure that the Wireless parameters of the Client case sensitive SSID 802 11 mode radio channel and security match those of the AP Check the radio conditions distance between devices plac...

Page 9: ...ANTENNA 1 AND 2 Radio modes Support for IEEE 801 11a h 802 11b 802 11g 802 11n and 802 11ac Frequency band for 802 11a n 5 GHz 5 170 to 5 835 GHz Frequency band for 802 11b g n 2 4 GHz 2 402 to 2 494...

Page 10: ...n 5 GHz 5 170 to 5 835 GHz Frequency band for 802 11b g n 2 4 GHz 2 402 to 2 494 GHz Tx output power Radio card output per chain antenna excluded 802 11b 2 4GHz band 20 dBm 1 Mbps 20 dBm 11 Mbps 802 1...

Page 11: ...3 5 35 4 Group IIC 2 33 0 Group III 6 37 7 The above threshold level refer to installation in classified area Ex according to IEC EN 60079 0 standard The use of device differs from one region and or...

Page 12: ...Mb SWS series only IP66 68 Atex certificate number EXA 14 ATEX 0042 IECEx identification Ex db IIC T5 T4 Gb Ex tb IIIC T110 C T140 C Db Ex db I Mb SWS series only IP66 68 IECEx certificate number IEC...

Reviews: