background image

-

2

 

HARDWARE INSTALLATION

 

 

1. 

Plug the antennas 

 

Plug the antennas of your choice (not provided as standard) on the QMA type 
connectors of WiFi interfaces). 

Whatever the WIFI interface (WiFi 1 and/or WiFi2): 

  For a single antenna installation, use the ANT1 connector. 

  For an installation with 3 antennas, use ANT1, ANT2 and ANT3 

connectors 

 

 

WARNING: 

It is recommended to connect a 50 ohms terminator on unused 
antenna connector. If not, it may disturb radio link quality and data 
throughput, and as well as waterproofness.

 

 
2.  Connect the power supply 

See  the  “

specifications

”  section  about  the  characteristics  of  the  power 

supply.

 

 
The  device  has  no  ON/OFF  switch. It  turns-on  automatically  when  power  is 
applied. Check LEDs Power1 and Power2: 

 

Power1 LED is ON if POWER1 power supply or PoE+ source is 
ON. 

 

Power2 LED is ON if POWER2 power supply is ON. 

 
 
The  device  has  no  ON/OFF  switch. It  turns-on  automatically  when  power  is 
applied. Check LED Power 

 

Power1 LED is ON if Power1 power supply or 

PoE 

source is ON. 

 

Power2 LED is ON if Power2 power supply is ON. 

 
The Diag LED stays red for around 60 seconds, until the device is fully ready 
to use. Then the Diag LED turns green. 
 
PoE+ models must be exclusively powered by a PoE+ power source (802.3at 
type  2  class4)  connected  to  LAN2  connector  (the  use  of  the  POWER  M12 
connector on PoE+ models, is not functional). 
 

 
3.  Connect the Ethernet cable 

 

Plug the Ethernet cable to the device’s LAN1 or LAN2 M12 connector. 

 

Check that the corresponding LAN LED turns ON at that point. 

Summary of Contents for RailBox Series

Page 1: ...irmware du produit T l charger et lire le manuel WaveOS user guide Vous aurez besoin de un PC Windows pour installer le logiciel WaveManager un navigateur internet r cent un smartphone Android pour in...

Page 2: ...cations pour les caract ristiques de l alimentation Le produit n a pas de bouton Marche Arr t il d marre automatiquement d s la mise sous tension V rifiez les voyants Power 1 et Power 2 Power 1 s allu...

Page 3: ...te WEB ACKSYS www acksys fr S lectionnez votre produit et cliquez sur Configurer Vous pouvez alors configurer son adresse IP afin qu elle soit compatible avec votre r seau ou encore activer le client...

Page 4: ...vous devez choisir l utilisateur root Par d faut il n y a pas de mot de passe Cliquez sur Login pour acc der au menu SETUP a Vous devez activer l interface radio afin de configurer les param tres Wi F...

Page 5: ...Mesh Les param tres Wi Fi Mode 802 11 canaux Prendre en compte la l gislation en vigueur dans votre pays SSID Les param tres de s curit WEP WPA WPA PSK WPA2 WPA2 PSK SSID diffus ou pas Vous trouverez...

Page 6: ...92 168 1 1 Remarque Tant que le bridge n est pas connect au point d acc s le voyant State clignote PROBLEMES ET SOLUTIONS Aucun voyant ne s allume sur le produit V rifiez la source d alimentation tens...

Page 7: ...il repasse en vert signalant que le produit a red marr en configuration usine Refermez le capot en Resserrant toujours les 4 vis du capot en diagonale en appliquant un couple de 2Nm RESET Un bouton RE...

Page 8: ...TM Molex permet de monter dans l embase un c ble quip du m me syst me sans le visser Connecteurs Ethernet M12 Deux ports LAN1 et LAN 2 Connecteur M12 8 p les femelle codage X visser Nom du signal Pin...

Page 9: ...femelle Wi Fi 2 Antennes pour interface WiFi 2 Nom du signal Fonction Ant 1 Cha ne RF 1 Ant 2 Cha ne RF 2 Ant 3 Cha ne RF 3 Les configurations d antennes possibles d utiliser pour les deux interfaces...

Page 10: ...faillance mat rielle Vert Fonctionnement normal Clignotant Le firmware est en cours de chargement ou le produit est mode emergency upgrade car le firmware est corrompu le recharger avec WaveManager L...

Page 11: ...CONTACT D ALARME Le produit dispose d un contact pour signaler l apparition d un v nement pr alablement configur Les broches Contact d alarme du connecteur M8 sont utilis es cet effet Ce contact est...

Page 12: ...e fixation de la platine sur le support ne sont pas fournies trou oblong 6 5 mm Plan de la platine Dimensions en mm MISE A LA TERRE Il existe 2 possibilit s pour relier le produit la terre 1 Utilisati...

Page 13: ...fonctionnement 40 C 70 C 40 F 158 F Temp rature de stockage 40 C 85 C 40 F 185 F Bouton Reset Appui court 1 sec tout moment Reset Appui long 2 sec pendant le fonctionnement Retour aux valeurs d usine...

Page 14: ...les codage A Supporte galement la tension nominale 24VDC selon la norme EN50155 Consommation max de 25W Mod le cod P PoE Le produit doit tre exclusivement aliment par une source PoE 802 3af at type 2...

Page 15: ...Utile pour les topologies daisy chain LAN1 et LAN2 court circuit s en cas de panne produit ou panne d alimentation Contact d alarme Type Relais Statique 1 forme A normalement ouvert Tension max 60VDC...

Page 16: ...an HT20 18 dBm MCS 0 13 dBm MCS 7 802 11an HT40 17 dBm MCS 0 12 dBm MCS 7 Sensibilit de r ception l entr e de la carte radio ajouter 2dBm pour avoir la sensibilit sur le connecteur type QMA Tol rance...

Page 17: ...13 dBm MCS 7 802 11an HT40 18 dBm MCS 0 12 dBm MCS 7 802 11ac HT20 18 dBm MCS 0 12 dBm MCS 9 802 11ac HT40 18 dBm MCS 0 11 dBm MCS 9 802 11ac HT80 18 dBm MCS 0 10 dBm MCS 9 Sensibilit de r ception l...

Page 18: ...type 2 ID TK4WLE900VX N Titre EN301 489 17 CEM pour quipement radio 2 4GHz 5GHz EN300 328 Norme radio 2 4 GHz EN301 893 Norme radio 5 GHz EN60950 S curit lectrique Le produit avec l alimentation 24 11...

Page 19: ...nload and read the full manual WaveOS user guide You will need a PC equipped with Ethernet access to install the WaveManager software a web browser IE compatible an android smartphone if you want to i...

Page 20: ...h It turns on automatically when power is applied Check LEDs Power1 and Power2 Power1 LED is ON if POWER1 power supply or PoE source is ON Power2 LED is ON if POWER2 power supply is ON The device has...

Page 21: ...anager found in web site www acksys com Select the device and click on Setup button You can configure the IP address to make it compatible with your network or activate the DHCP client 5 Product WEB I...

Page 22: ...password is required by default click on Login You get now access to the setup pages In the wireless interfaces overview section you must a Enable the Wi Fi radio interface to set up its Wi Fi parame...

Page 23: ...Access point client bridge Wi Fi parameters 802 11 mode radio channel SSID Wi Fi security parameters WEP WPA WPA PSK WPA2 WPA2 PSK SSID broadcast or not You will find a complete description of all mod...

Page 24: ...1 verify the answer returned by PC1 Answer from 192 168 1 1 Notice The State LED is flashing until the bridge connects to the AP TROUBLESHOOTING None of the LED indicators turns ON Verify the power su...

Page 25: ...for the Diag LED to turn green again meaning that the product rebooted with its factory settings Close the product by tightening the screws to a torque of 2Nm 10 RESET Reset button is attainable by un...

Page 26: ...he ULTRA LOCK feature enables to connect a cable with a simple Plug to create a perfect connection M12 Ethernet connectors Two Ports LAN1 and LAN2 M12 SPEEDCONNEC 8 poles female connector X coded Sign...

Page 27: ...Ant 3 RF Chain 3 Wi Fi 2 connector female QMA type Wi Fi 2 antennas Signal name Function Ant 1 RF Chain 1 Ant 2 RF Chain 2 Ant 3 RF Chain 3 The antennas configurations for the two WiFi1 and WiFi2 int...

Page 28: ...Green Red for more 120s hardware failure Green Ready to use Blinking Firmware in flash is loading Device is in emergency mode because firmware is corrupted Re load firmware with WaveManager LAN 1 LAN...

Page 29: ...ovides an alarm contactor in order to signal a configuration defined event to the user The alarm uses Alarm contactor pins of the M8 connector The contact is closed during normal product operation and...

Page 30: ...ws for panel mounting are not included Drawing of the fixing plate All dimensions are given in mm EARTH GROUNDING Firmly connect the device to a suitable earth There are 2 ways to connect the product...

Page 31: ...3 F to 158 F Storage temperatures ranges for all version 40 C to 85 C 40 F 185 F Reset button Short push 1 sec anytime Reset Long push 2 sec while operating Restore factory settings while in emergency...

Page 32: ...5 24VDC nominal voltage polarity protection 4 pole M12 plug A coding Power supply requirement 25W Electrical connection requirement The circuit breaker must have a nominal current In compatible with t...

Page 33: ...l for daisy chain network topologies Connect LAN1 to LAN2 in case of device or power supply failure Alarm contact Type Solid state relay 1 form A NO Normally Open Max voltage 60VDC not polarized prote...

Page 34: ...13 dBm MCS 7 802 11an HT40 17 dBm MCS 0 12 dBm MCS 7 Rx sensitivity radio card input Add 2 dBm to get the value available at the QMA TYPE RF connector Tolerance 2dB 3 antennas 802 11g 95 dBm 6M 81 dBm...

Page 35: ...MCS 0 12 dBm MCS 7 802 11ac HT20 18 dBm MCS 0 12 dBm MCS 9 802 11ac HT40 18 dBm MCS 0 11 dBm MCS 9 802 11ac HT80 18 dBm MCS 0 10 dBm MCS 9 Rx sensitivity radio card input Add 2 dBm to get the value a...

Page 36: ...Radio interface type 1 and 5 ID W23 JWX6082 Radio interface type 2 ID TK4WLE900VX The device with 24 110V power supply also complies with EN50155 Electronic equipment used on rolling stock EN50155 EN5...