errors that may be contained in this document, or for damages, no matter what their extent, that result from the supply, operation or use of the products. In its ongoing efforts to improve its documentation, ACKSYS reserves the right to revise this document periodically or to change all or part of its 
content, without incurring any obligation to notify any party whatsoever. 

Ethernet AIR-PACK 

User guide 

 

 

  Plug and play, zero configuration 

  Compact metal housing  

  Wall or DIN Rail mounting 

  100-240Vdc Power supply 

 

DELIVERY PACKAGE

 

 
The following kit parts are included in the delivery : 

-

 

2 Ethernet AIR-PACK Wi-Fi modules 

-

 

This documentation 

-

 

2 crossing Ethernet cables 

-

 

2 omnidirectional

 

antennas (for V2 version) or 

4 omnidirectional

 

antennas (for V3 version) 

-

 

2 external DC power supplies 

-

 

2 Din rail-mounting kits. 

 
If an item is missing, please contact your distributor. 
 

STEP 1 : Get started 

 
Unpack the modules and accessories (cables, antennas, power supplies). Check that all 
needed parts are available. You can begin installation. 
 

STEP 2 : Installing  

 
Plug an antenna, an Ethernet cable and a power supply in each module. 
Attach the Ethernet cables to the devices you wish to link through the Ethernet AIR-PACK 
modules. 
Plug the power supplies in a wall outlet. 
 

STEP 3 : Using 

 
Once the blue and red LEDs stop blinking alternately, the two Ethernet AIR-PACK 
modules are interconnected and are ready to use.  
 
Your Ethernet devices can now communicate normally, there is no need to change the 
network configuration.  

 

THE DISPLAY LEDS 

 
Both modules show their state using five LEDs. 
 

Power

: Green LED 

-

 

This LED turns on when power supply is correctly applied to the module.  

 

10/100 Base Tx

 : Green LED 

-

 

This LED turns on when a 100Base TX Ethernet link is used. 

 

Link (Lan) Tx/Rx

 : Green LED 

-

 

This LED turns on when the Ethernet link is established, and blinks when 
transferring data to and from the Ethernet network. 

 

Diag

: Red LED 

-

 

This LED turns on for less than 10 seconds after powering up, until the module has 
initialized; then it turns off. 

 
If the LED stays alight for more than 10 seconds after powering up, it means that the 
module is malfunctioning. Try to power down and power up again. 
 

WLan Tx/Rx

: Blue LED 

-

 

This LED blinks when transferring data to and from the Wi-Fi network. 

 

Diag + Wlan Tx/Rx: 

-

 

When these two LEDs blink alternately, the two modules cannot connect to each 
other. Change the orientation of the antennas or  move the modules to another 
place. 

 

MODULE RESET 

 
Each module is equipped with a two-functions 

pushbutton

 near the Ethernet connector:  

-

 

With a quick push (< 1 second) the button resets the module. 

-

 

With a long push (> 2 seconds) the button resets the factory default settings of the 
module. 

 

OPTIONAL CONFIGURATION 

 
The AIR-PACK modules are preconfigured and do not need any configuration to be used. 

However, if you wish, you can change some configuration settings. These changes must 
be made after careful planning. Uncontrolled changes may disrupt correct functioning of 
the Ethernet AIR-PACK. 
 

WARNING

: In their default configuration, all AIR-PACK modules have the same IP 

address (192.168.1.253), used only for administration. Hence, in order to access one 
module’s administration menus, you must connect the module directly to your computer 
through their Ethernet plugs, and you must power down the other module during 
configuration. The network configuration of your computer must be compatible with the 
default module IP address and with the network mask 255.255.255.0. Call your network 
administrator to reconfigure your computer if needed. 
 
Connecting to the administration WEB pages :  
 

The AIR-PACK modules have an embedded WEB server. To access it, start 

your web browser and type the following URL

http://192.168.1.253

. There is no password 

for user “admin” in the default settings. 
 
Network configuration changes:  
 

If you wish to change the module IP address or to activate the DHCP client, 

connect to the administration, and go to the BASIC

LAN menu.  

 
Wi-Fi configuration changes: 
 

In the Wi-Fi configuration page you can only change the allowed 

transmission speeds, and (for the module set to ACCESS POINT mode) the radio channel 
(the module set to BRIDGE mode automatically selects the access point’s own channel).  
 

Once connected to the administration, go to the BASIC

WIRELESS menu.  

 

TROUBLESHOOTING 

 

1. 

Check the Ethernet AIR-PACK configuration 

 
In order to check the Ethernet AIR-PACK  configuration, move the two modules so that 
they are close to each other. Power up both modules and wait for the blue and red LEDs 
stop blinking alternately. If the alternate blink does not stop after one minute, the products 
are not properly configured. Reset both modules to factory settings and retry. 
 
 

TECHNICAL  CHARACTERISTICS  

 

Ethernet link 

10/100 Base Tx, RJ45 (with auto MDI/MDIx for V3 
version) 

Wi-Fi link  

802.11a 
(5GHz) 

1 omnidirectional antenna, 2dBi, 
for V2 version 
2 omnidirectional antennas, 2dBi, 
for V3 version 

Maximum transmitted output power  
(+/- 1.5dBm) 

6 to 24 Mbps : 20 dBm 

36 Mbps : 17 dBm 
48 Mbps : 16 dBm 
54 Mbps : 13 dBm 

Receiver sensitivity 

6 Mbps :    -90 dBm 

54 Mbps :    -70 dBm 

Security 

Preset WPA2-PSK, SSID broadcast disabled 

Consumption (each module) 

3.5W typ., 5.5W Max 

Power supply 

Jack 5VDC, with 100-240 V power supply, for V2 
version 
 9 to 48 VDC, handles wires inversion,  with 100-
240 V power supply, for V3 version 

Operating Temperature 

0°C to +70°C 

Storage Temperature 

-20°C to +80°C 

Humidity 

5% to 95% no-condensing 

Dimensions (each module) 

L: 103.00 x W: 67.00 x H: 24.00 mm  

Weight (each module) 

~230 g 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

10, rue des Entrepreneurs  

 Z.A Val Joyeux 

78450 VILLEPREUX - France 

Phone:  

+33 (0)1 30 56 46 46 