Technical Specifications
TECHNICAL SPECIFICATIONS
(subject to change without notice)
Measurement range (Vrms)
30Vac to
300Vrms (Ph
– N)
Maximum channel input voltage
300Vrms (Ph
– N)
Voltage Measurement accuracy
±1% of reading
(10 bit) within 50Vac
– 300Vrms (Ph
– N); else ±3%. (50/60Hz ±2%)
Current Range
0.1A
– 15A (other ranges can be factory set)
Current Measurement Accuracy
3% of range, 1 to 13A. 0.1 to 1A, +/- 0.1A.
Vmin & Vmax meas time resolution
Always one cycle (50/60 Hz), independent of
selected averaging period.
Sampling frequency
16 samples per cycle
800Hz @ 50Hz
or
960Hz @
60Hz
Data recorded
Average voltage/current, max & min voltage/current-
cycle-value during the averaging period
Memory capacity
128kB able to record 32,000 Voltage levels per
channel.
Memory type
Non-volatile SEEPROM
Memory - averaging period & duration
1 sec to 60 mins (1sec. avg gives 2 hrs of logging,
60min. avg gives 300 days of logging)
Real-time clock accuracy
Greater than 0.001%
Lead Lengths
Metric
1.0 metres
Imperial
3’ 6” (3 feet, 6 inches)
Battery life (while plugged in)
Unlimited - mains powered & battery backup (9,000
hours, 1 year while unpowered).
Battery Type
Unit contains
three
9V Alkaline batteries (E-Block,
PP3, 1604A).
Communications Interface type
USB, baud of 19,200
Electrosoft Software
Windows (9x, 2K, ME, NT, XP, Vista, Win 7, 8);
1024 x768 min resolution
Environmental (temp & sealing)
-20C to +40C
/
+14°F to +104°F
–
Indoor use only
Dimensions & Weight
Metric
230 x 140 x 50mm &
400g
Imperial
– 5.5” x 3.5” x 2” & 1lb
Standards
Recording - EN50160: 1994 - CAT II, maximum
input voltage 300Vac.
Calibration
Each unit is individually calibrated during testing.
Battery life (while connected)
Unlimited - mains powered and battery back up.
Battery life (while unconnected to mains)
The 9V Alkaline batteries should last for at least 9,000 hours (1 year),
Caution
The battery used in this device may present a risk of fire or chemical burn if mistreated.
Do not recharge, disassemble, heat above 100°C or incinerate. Replace with a 9V Lithium
or Alkaline battery IEC Type 6-F22 (PP3, MN1604). Use of another battery may present a
risk of fire or explosion. Dispose of used batteries promptly. Check for signs of battery
(electrolyte) leakage. If leakage has occurred, the PCB must be cleaned in an approved
manner by a competent (trained) person. Keep away from children. When replacing
batteries, ensure the new batteries are secured to the battery holders with cable-ties or
tie-wraps.
Maintenance
Regularly check the Electrocorder casing for signs of damage (cracks, broken or loose
parts) or misuse. If the unit is damaged in any way it must
NOT
be used and should be
returned to the supplier. The unit must not be used for any other purpose than for that
recommended by the manufacturer. The unit must not be submerged in any liquid.
Cleaning
Wipe the outside of the case with a clean cloth damped with IPA (Isopropyl Alcohol).
Warranty
All Acksen products carry a minimum 1 year’s warranty covering manufacturing defects and
component failures. The device contains no user-serviceable parts
and as such should only
be repaired by skilled and authorised personnel. Failure to comply could result in unsafe
operation and should not be attempted under any circumstances. Contact below for a list of
approved service agents.
Note:
Any unauthorised repair or adjustment will automatically render the warranty invalid.
Repair and spare parts
Acksen Ltd.
28 Station Road
Whiteabbey
Newtownabbey
Co. Antrim BT37 0AW
United Kingdom
Or an approved repair company.
Returning a product for repair
If returning a product to the manufacturer for repair, it should be sent freight pre-paid to the
appropriate address. A copy of the Invoice and of the packing note should be sent
simultaneously by airmail to expedite clearance through Customs. A repair estimate showing
freight return and other charges will be submitted to the sender, if required, before work on
the device commences.
WEEE
For EU customers Acksen Ltd offer a product take-back service. For customers within the
European Union (only) and products manufactured or sold by us; when those products
reach the end of their life, simply send them back to us at your expense, we will dispose of
them according to the relevant legislation. WEEE Reg. No. WEE/DD2117VU.
Part No: AL-2VA-UI-En.PDF
Email: [email protected]