ACIQ ACiQ-24-HPB Quick Start Manual Download Page 4

18/8 thermostat wire will be 

required for correct low voltage 

wiring. A common color scheme is 

shown in the diagram, but please 

note colors may vary.

Backup Heat Type:

 Set To Gas/Oil Furnace

Outdoor Temperature Sensing:

 Varies Based On Thermostat (Wi-Fi, Wired, Or Wireless Sensor)

Lockout/Switchover Temperature:

 Varies Based On Desire For Greater Efficiency Or Comfort. Maximum 

Comfort = 35 °F, Maximum Efficiency = -10 °F, Our Recommendation = 0 °F

IMPORTANT – the heat pump and the furnace should NEVER run at the same time.  Most heat pump 

thermostats are already configured to prevent this from happening.  

Thermostat wiring to the terminals 

on the furnace will vary based on 

the brand of the thermostat.  Please 

refer to the thermostat manual for 

furnace wiring.  Look for a section 

on dual fuel wiring.  Some 

thermostats send the call for 

backup heat over the W terminals 

as shown. Some send the backup 

call over Aux/E.

Typical Wiring Example

Reversing Valve (O/B): 

Set To Energized In Heating Mode (Opposite Of Most Default Settings)

2023 V1.0

Thermostat Wiring

IMPORTANT

 – Every thermostat is different.  Modern thermostats will have an “Installer Setup” or 

“Advanced Options” mode.  A dual fuel setup 

requires

 a heat pump compatible thermostat, which 

will call on the furnace only as backup heat at extreme low temperatures.  Here are general 

guidelines – refer to your thermostat manual for specifics.

Installer Setup & Advanced Options Settings

System Type:

 Set To Dual Fuel

Summary of Contents for ACiQ-24-HPB

Page 1: ...purchasing an ACiQ Next Generation heat pump condenser Using this system in a dual fuel application will dramatically reduce your heating costs in the winter compared to a standard system setup The heat pump will provide heat in most conditions and the furnace will provide backup heat at extreme low temperatures ACiQ 24 HPB ACiQ 36 HPB ACiQ 48 HPB ACiQ 60 HPB ...

Page 2: ... unit It is permissible to oversize the indoor coil by up to 1 ton 12 000 BTU H 3 A 24 volt heat pump thermostat with a minimum of 2 stages of heating and 2 stages of cooling must be used 2H 2C 4 The selected thermostat must have a wired wireless or internet based outdoor temperature sensing feature STANDARD HEAT COOL ONLY THERMOSTATS WILL NOT WORK FOR THIS APPLICATION REFRIGERANT CONNECTIONS IMPO...

Page 3: ...1 0 System Setup SET DIP SWITCHES AS SHOWN Reference Guides D L L1 L2 R C Y1 Y2 B W Wired To Selected Indoor Unit Reversing Valve Energized In Heating Heat Cool Stage 2 High Demand Heat Cool Stage 1 24 Volt Common IGNORE DO NOT USE IGNORE DO NOT USE IGNORE DO NOT USE 24 Volt Hot Power ...

Page 4: ...minals on the furnace will vary based on the brand of the thermostat Please refer to the thermostat manual for furnace wiring Look for a section on dual fuel wiring Some thermostats send the call for backup heat over the W terminals as shown Some send the backup call over Aux E Typical Wiring Example Reversing Valve O B Set To Energized In Heating Mode Opposite Of Most Default Settings 2023 V1 0 T...

Reviews: