background image

Page 12

Page 13

����

15/03/04

COAX > 50mt.

VPE71S102

22701B

22701COLB

3

1 2

C

5

4

R

* ELECTRIC LOCK

MAX 700mA

21809

12,2 VAC 1,5A

230 VAC

F

U

S

E

22722_10609

OR

10609COL

���

���

� � �

� � �

2

7

10

21

0

T2

T1

10

1

2

3

4

5

6

7

8

9

11

12

+

22803

13,4 VDC 400mA cont.
12,5 VDC 550mA interv.

230 VAC

F

U

S

E

���

���

� � �

� � �

-

N

MONITOR T2

22701B

22701COLB

MONITOR T1

22701B

22701COLB

2

1

5

4

3

N

2

1

5

4

3

N

1017C

4

3

22

μ

F

2,7V

68 Ohm

�����������

��������������

��� �����

����

������ ��

���������

������ ��

���������

������

������

� � ����

10210

21809

�����

22803

�����

�����������

������

Summary of Contents for ELLISSE 22701B

Page 1: ...Page 1 INSTALLATION MANUAL FOR ELLISSE 22701B AND 22701COLB VIDEO SYSTEMS 8 APRILE 2004 acet around the world s r l ...

Page 2: ...ving the packing check the integrity of the set Packing components plastic bags expanded polystyrene etc are dangerous for children Installation must be carried out according to national safety regulation 3 A safety switch installed before the power supply is recomended 4 Before connecting the set ensure that the data on the label corresponds to the local supply voltage 5 Use this set only for the...

Page 3: ...AL BOARD MONITOR Fix the mounting plate on the wall with 2 screws and slide the monitor paying attention to the correct centering on the 4 holders figure 2 PUSH BUTTON PANEL Install the external panel with the camera at about 160 cm 5 ft from ground Unlock the panel with the enclosed key and open the panel The name tag holder is now accessible for inserting the name tag figure 3 ...

Page 4: ...pen the door 5 Replace the telephone on the monitor After 5 seconds the system is ready for a new call figure 4 PICTURE RECALL Push the button with the circle inside the square the monitor will be working for about 30 secondos after 10 seconds is possible repeat the operation ADJUSTMENT OF CALL VOLUME BRIGHTNESS AND COLOR OF MONITOR ELLISSE 22701COL On the bottom of the monitor are placed three po...

Page 5: ...ectric lock and speaker amplifier 2272X Length of cable mtrs 8 16 24 40 Wire section mmq 1 1 5 2 5 4 Wire diameter mm 1 14 1 38 1 78 2 25 for electric lock that requires more than 12VA use the relay 10076 and an additional power supply Between monitor 22701 and speaker amplifier 2272X a no coax used and one transformer 21809 for the speaker amplifier and one power supply 21847 22803 for the monito...

Page 6: ...upply of monitor 2 Speach line speaker amplifier monitor 3 GND for video conversation and power 4 Output for video signal 5 Output for picture recall 6 GND parallel to Pin 3 7 8 Output for call signal 9 Output to electric lock 10 Electric lock power supply parallel to Pin 11 11 Ground GND AC power 12 AC Power terminal AC Voltage DC Voltage Measurement or description 11 12 12V 12 5 V Stand by 11 12...

Page 7: ...dio and picture are present but the electric lock doesnʼ t work 1 Verify the electric lock with a direct voltage input 2 Link t p 2 to t p 3 and check the voltage between t p 9 and t p 10 of 2272X which should be about 6 5 V AC 3 Check the same voltage on the electric lock If it is lower not high enough for lock operation verify the cables between the 2272X and the electric lock If the cables are ...

Page 8: ...chematic APPENDIX 4 BAD CONNECTION ON ELLISSE VIDEO SYSTEMS In this section will be examinated the problems due at connection mistakes or wires reversal A SINGLE INVERSION 1 Inversion wires 1 2 System doesnʼt work 2 Inversion wires 1 3 Audio and picture donʼt work call tone low 3 Inversion wires 1 4 Call and audio well picture doesnʼt work 4 Inversion wires 1 5 Call and audio well picture doesnʼt ...

Page 9: ...3 230 VAC FUSE 0 230 0 12V 1 2 3 4 5 6 10076 12 24V 5A 700mA 9 of 22722 10 OF 22722 21809 12 2 VAC 1 5A 230 VAC FUSE 0 230 0 12V 1 2 4 5 1 2 4 3 5 ATTENTION 13 4 VDC 400mA cont 12 5 VDC 550mA interv 2 7 10210 4 3 22μF 2 7V 68 Ohm 1017C 230V AC 21809 2 MAX 12VAC 0 7A 2 2272X_10609 2272X_10609COL 22701B or 22701COLB 1017C COAX 2 UNVPE71S101 22803 10210 DASHED LINES MEAN CONNECTIONS MADED FROM CONSTR...

Page 10: ...LOCK MAX 700mA 21809 12 2 VAC 1 5A 230 VAC FUSE 22722_10609 OR 10609COL 2 7 10210 10 1 2 3 4 5 6 7 8 9 11 12 N MONITOR T1 22701B 22701COLB 2 1 5 4 3 N MONITOR T2 22701B 22701COLB 2 1 5 4 3 N 4 3 68 Ohm 1017J MONITOR T3 22701B 22701COLB 2 1 5 4 3 N T1 230V 0 2A 0 4A 9 8 21847 13 VDC 1 4A ...

Page 11: ...5 4 R ELECTRIC LOCK MAX 700mA 21809 12 2 VAC 1 5A 230 VAC FUSE 22722_10609 OR 10609COL 2 7 10210 T1 10 1 2 3 4 5 6 7 8 9 11 12 N MONITOR T1 22701B 22701COLB MONITOR T2 22701B 22701COLB 2 1 5 4 3 N 2 1 5 4 3 N 2A 0 4A 9 8 21847 230V 0 13 VDC 1 4A 1017C 4 3 22μF 2 7V 68 Ohm ...

Page 12: ...mA 21809 12 2 VAC 1 5A 230 VAC FUSE 22722_10609 OR 10609COL 2 7 10210 T2 T1 10 1 2 3 4 5 6 7 8 9 11 12 22803 13 4 VDC 400mA cont 12 5 VDC 550mA interv 230 VAC FUSE N MONITOR T2 22701B 22701COLB MONITOR T1 22701B 22701COLB 2 1 5 4 3 N 2 1 5 4 3 N 1017C 4 3 22μF 2 7V 68 Ohm 10210 21809 22803 ...

Page 13: ...2 VAC 1 5A 230 VAC FUSE 22722_10609 OR 10609COL 2 7 10210 10 1 2 3 4 5 6 7 8 9 11 12 N MONITOR T1 22701B 22701COLB 2 1 5 4 3 N MONITOR T2 22701B 22701COLB 2 1 5 4 3 N MONITOR T3 22701B 22701COLB 2 1 5 4 3 N T2 T1 T3 22803 13 4 VDC 400mA cont 12 5 VDC 550mA interv 230 VAC FUSE 1017C 4 3 22μF 2 7V 68 Ohm ...

Page 14: ... 7 8 9 11 12 23 03 04 VPE71S104 22701B 22701COLB 3 1 2 C 5 4 R N MONITOR T1 22701B 22701COLB 2 1 5 4 3 N MONITOR T2 22701B 22701COLB 2 1 5 4 3 N MONITOR T3 22701B 22701COLB 2 1 5 4 3 N T2 T1 T3 22803 13 4 VDC 400mA cont 12 5 VDC 550mA interv 230 VAC FUSE MONITOR T4 22701B 22701COLB 2 1 5 4 3 N T4 1017C 4 3 22μF 2 7V 68 Ohm ...

Page 15: ... 22701B 22701COLB 3 1 2 C 5 4 R N MONITOR T1 22701B 22701COLB 2 1 5 4 3 N MONITOR T8 22701B 22701COLB 2 1 5 4 3 N MONITOR T9 22701B 22701COLB 2 1 5 4 3 N T1 22803 13 4 VDC 400mA cont 12 5 VDC 550mA interv 230 VAC FUSE MONITOR Tn 22701B 22701COLB 2 1 5 4 3 N Tn T9 T8 22803 13 4 VDC 400mA cont 12 5 VDC 550mA interv 230 VAC FUSE 1017C 4 3 22μF 2 7V 68 Ohm ...

Page 16: ... BETWEEN T P 1 AND 3 11 2 13 5 VDC ON MONITOR 22701COL BETWEEN T P 1 AND 3 12 2 13 5 VDC ON MONITOR 22701B 22701COLB BETWEEN T P 2 AND 3 MORE THAN 6VDC EVERY 8 MONITOR ADD 1 POWER SUPPLY IF THE TENSION IS LOWER THAN 10 5VDC THE MONITOR DONʼT TURN ON THIS IS DUE TO THE SELF PROTECTION CIRCUIT SYSTEM AUDIO WORK NORMALY BUT THERE COULD BE NOISE ON THE SIGNAL 10210 21809 22803 22803 22803 ...

Reviews: