background image

ACER XV240Y 

 

3

 

 

 

Important Safety Notice 

 

Product Announcement: 

This product is certificated to meet RoHS Directive and Lead-Free produced definition. Using approved 
critical components only is recommended when the situation to replace defective parts. Vender 
assumes no liability express or implied, arising out of any unauthorized modification of design or 
replacing non-RoHS parts. Service providers assume all liability. 

 

 

Qualified Repairability: 

Proper service and repair is important to the safe, reliable operation of all series products. The 

service providers recommended by vender should being aware of notices listed in this service 
manual in order to minimize the risk of personal injury when perform service procedures. 
Furthermore, the possible existed improper repairing method may damage equipment or products. It 
is recommended that service engineers should have repairing knowledge, experience, as well as 
appropriate product training per new model before performing the service procedures. 

NOTICE: 

To avoid electrical shocks, the products should be connect to an authorized power cord, and turn 

off the master power switch each time before removing the AC power cord. 

To prevent the product away from water or explosed in extremely high humility environment. 

To ensure the continued reliability of this product, use only original manufacturer

’s specified parts. 

To ensure following safety repairing behavior, put the replaced part on the components side of 

PWBA, not solder side. 

To ensure using a proper screwdriver, follow the torque and force listed in assembly and 

disassembly procedures to screw and unscrew screws. 

Using Lead-Free solder to well mounted the parts. 

The fusion point of Lead-Free solder requested in the degree of 220°C.

Summary of Contents for XV240Y

Page 1: ...Acer Monitor XV240Y LIFECYCLE EXTENSION GUIDE ...

Page 2: ... 3 Mechanical Instruction 6 4 Disassembly and Assembly SOP 7 5 Troubleshooting 13 6 FRU List 15 Safety Notice Any person attempting to service this chassis must familiarize with the chassis and be aware of the necessary safety precautions to be used when serving electronic equipment containing high voltage ...

Page 3: ...airing method may damage equipment or products It is recommended that service engineers should have repairing knowledge experience as well as appropriate product training per new model before performing the service procedures NOTICE To avoid electrical shocks the products should be connect to an authorized power cord and turn off the master power switch each time before removing the AC power cord ...

Page 4: ...ODM DESCRIPTION Item ODM DESCRIPTION 1 ASSY TRIM 14 FFC LVDS 2 PCBA LED BD 15 ASSY SHD 3 LAMP WIRE 16 LVDS WIRE 4 LCDM 17 SCRW 5 MID FRAME 18 ASSY RC 6 SCRW 19 PCBA CTRL BD 7 SPK 20 ASSY CLMN 8 SCRW 21 ASSY BASE 9 MYLAR 10 PCBA SPS BD 11 PCBA IF BD 12 MYLAR SHD 13 SCRW ...

Page 5: ...iagrams for model XV240Y The wiring connectivity position will be different according to the ACTUAL PCBA connector position Please base on different SKU refer to below diagram NOTE INF BD Interface Board PWR BD Power Board CTRL BD Control Board 1 SKU with USB 2 SKU without USB ...

Page 6: ... tools that would typically can be used to disassemble the product to a point where components and materials requiring selective treatment can be removed Tool Description working table Screw driver Philips head screwdriver Hex head screwdriver Knife glove cleaning cloth ESD protection ...

Page 7: ... protection After unplugging the power cord the power board still have power energe Please pay attention when disassembling assembling S1 Disassemble the RC stand and base Before Disassembling Assembling monitor need to be put on the sponge and the Insulation glove must be wore during the process Unlock 4 screws to disassemble base and stand from the RC Rear Case and Unlock RC center screw as pict...

Page 8: ...d tear off the wire from the SHD as picture 3 PICTURE 1 PICTURE 2 PICTURE 3 S4 Disassemble ASSY Trim Unlock 2 TRIM screws and disassemble the ASSY TRIM from the MF as picture 1 Disassemble the LED BD from the Trim and extract the LED wire from the LED BD as picture 2 PICTURE 1 PICTURE 2 S5 Disassemble SHD and MF Extract 2 FFC wires from the panel as picture 1 Unlock 9 screws from the MF and disass...

Page 9: ...he I F BD from the SHD and extract the P BD wire the FFC LVDS from the I F BD Disassemble the P BD from the SHD PICTURE 1 PICTURE 2 PICTURE 3 NOTE Circuit boards 10 cm has been highlighted with the yellow rectangle as above image shows Please detach the Circuit boards and follow local regulations for disposal I F BD P BD I F BD I F BD ...

Page 10: ...tor need to be put on the sponge and the Insulation glove must be wore during the process Put the SHD on the worktable Locate the P BD into the SHD Insert FFC LVDS to the I F BD Insert the wire on the P BD to the I F BD Locate the I F BD into the SHD Lock 6 screws to PCBA and stick 1 mylar to fasten the wire on the SHD as picture 2 Assemble the Mylar on the SHD as the picture 3 PICTURE 1 PICTURE 2...

Page 11: ...re to P BD as picture 1 Paste 1 mylar on SHD as picture 2 Tear off the 4 gums on the LED wire arrange the LED wire and insert the LED wire into the I F BD PICTURE 1 PICTURE 2 S5 Assemble SPK Assemble the SPK to the MF Insert the wire of SPK into the I F BD Arrange the wire of SPK and stick 4 pieces of black tapes to fasten the wire of SPK on the Panel Stick 1 piece of black tape to fasten the lamp...

Page 12: ...2 S7 Assemble the RC stand and base Insert the FFC CTRL to the IF BD and assemble the RC to the MF as picture 1 Lock 1 RC center screw and lock 4 screws to assemble the Stand and Base to Monitor as the picture 2 PICTURE 1 PICTURE 2 NOTE Circuit boards 10 cm has been highlighted with the yellow rectangle as above image shows Please detach the Circuit boards and follow local regulations for disposal...

Page 13: ... monitor is in compliance which may be causing the input signal frequency mismatch Display is missing center shift or too small or too large in display size Using OSD adjust RESOLUTION CLOCK CLOCK PHASE H POSITION and V POSITION with non standard signals Using OSD in case of missing full screen image please select other resolution or other vertical refresh timing Using OSD in case of missing full ...

Page 14: ...cord is properly connected to the monitor LED displays amber color Check if video signal cable is properly connected at the back of monitor Check if the power of computer system is ON Abnormal Sound Only Audio Input model Optional No sound or sound level is too low Check the audio cable with the host PC is connected Check if the volume setup of the host PC is in minimum position and try to raise t...

Page 15: ...inted Service Guide You MUST use the local FRU list provided by your regional office to order FRU parts for repair and service of customer machines NOTE To scrap or to return the defective parts you should follow the local government ordinance or regulations on how to dispose it properly or follow the rules set by your regional office on how to return it Category ACER DESCRIPTION Description PART ...

Reviews: