8
Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
Dark room (< 1 cd/m
2
)
Viewing distance
25-50 cm
Warm up time
>
30 minutes
Analog Input signal
700 mVss
Control temperature
6500
°
K
User brightness control
Set to Factory preset value (cut off raster)
User contrast control
Set to factory preset value, which allows that the brightest two of
32 linear distributed gray-scales (0
~
700mv) can be
distinguished.
Picture position and size
Factory preset value
Viewing angle
(H) 90
∘
+/-20
∘
and (V) 90
∘
+/-10
∘
AC Supply voltage
230V± 5
%
, 50±3Hz
Ambient temperature
20+5
℃
Humidity
65%
±
20%
Display mode
1680 x 1050, 60 Hz, all white
e-color mode
Set to “User” mode
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32
Degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76
Summary of Contents for X213H
Page 1: ...1 Acer X213H X223HQ Service Guide ...
Page 10: ...10 LCD Panel Specification General Specifications Block Diagram TFT LCD Module ...
Page 11: ...11 Back light Unit Electrical Characteristics ...
Page 12: ...12 Optical Specifications ...
Page 20: ...20 ...
Page 23: ...23 How to Adjust a Setting ...
Page 24: ...24 Adjusting the picture ...
Page 25: ...25 ...
Page 29: ...29 4 Remove the screws to remove the main board and power board 5 The panel ...