3.2. Operational Specification
3.2.1 Power supply
Item
Condition
Spec
OK N.A Remark
Input Voltage range
Universal input full range 90~264VAC /47~63Hz
Input Current range
90 ~ 264VAC
< 1.2 Arms
Power Consumption
Normal “On” operation
<
31W
LED: Blue
DPMS
DPMS “Sleep” state
< 2 W
LED: Amber
DPMS
DPMS “Off” state
< 1 W
LED: OFF
Inrush Current
110 VAC
220 VAC
< 30 A (peak)
< 60 A (peak)
Cold-start
Earth Leakage Current
264 VAC/50Hz
< 3.5 mA
Hi-Pot
1. 1500VAC, 1 sec
2. Ground test: 30A,
1sec
Without damage
< 0.1 ohm
(on-line test)
(in-lab test)
Power Line Transient
IEC1000-4-4
1KV
IEC1000-4-5 (Surge)
Common: 2KV,
Differential: 1KV
Power cord
Color: Black
Length: 1800 +/- 50 mm
Summary of Contents for X193HQL
Page 24: ...24 3 9 Packing...
Page 25: ...25 4 Disassembly Assembly 4 1 Exploded View Please see the next page...
Page 26: ......
Page 38: ...37 11 Disassembled the SPK shielding 4 screws Screw driver 12 Get off the panel from the bezel...
Page 45: ...44 Note you can change program speed bar to meet your equipment speed if program firmware fail...
Page 47: ...46 5 3 EDID Upgrade Procedure Step 1 Run the program Q EDID V012 exe when the UI popped up...
Page 51: ...50 Step 5 If read EDID is successful it shows Read EDID OK...
Page 52: ...51 5 4 OSD Operation Guide OSD Function Requirements...
Page 53: ...52...
Page 54: ...53...
Page 55: ...54 Remark Acer logo must be appeared while power on or suspend...
Page 57: ...56...
Page 71: ...70 Appendix 2 Physical Dimension Front View and Side view Fig 1 Appearance Description...
Page 72: ...71 Appendix 3 LED Driver...
Page 73: ...72 Appendix 4 Power Board...
Page 74: ...73 Appendix 5 Interface Board Please see next page...