X1160 Series/x1260 Series/X1160Z Series/X1260K Refresh
Confidential
6-3
6-4 EDID Key-In Procedure
- Take X1160 for example,X1260 /X1160 Refresh /
X1260 Refresh/X1160Z/X1160Z Refresh/X1260K
Refresh is the same as X1160
1. Click on "EDID" to execute EDID program
2. Choose model
(1) In the port selection bar, please choose
the port that you use. ie: if you use
"COM1", choose COM1 in the port
selection.
(2) Click on "Model".
(3) Choose the EDID that responses to the
model that you choose.
6-3 Setup Procedure
1.
Connect all ports
- Power adapter to fixture JP1
- Fixture P1 to PC COM1 Port
- Fixture P2 to Projector analog port
(1)
(2)
(3)
To Analog Por
t
RS232 Cable
JP1
P2
P1
Adapter