5
1.2 General Requirements:
1.2.1 Test Condition:
All tests shall be performed under the following conditions, unless otherwise specified.
Warm up time
> 30 min.
AC supply voltage
230V± 5%, 50± 3 Hz
Ambient temperature
20
C
5
C
Humidity
65%
20%
Display mode
1366 x 768, 60 Hz, all white
e-color mode
Set to “User” mode
Contrast control
Set to The value under user mode, which allows that the
brightest two of 32 linear distributed gray-scales (0
~
700mv)
can be distinguished.
Color temperature
6500°K
Brightness control
The value under user mode
Analog Input signal
700 mVss
Picture position and size
Factory preset value,
Viewing angle
90 ° H and V
Viewing distance
40 cm for LCD performance, 20 cm for LCD failures
Ambient illumination
Dark room (< 1 cd/m
2
)
1.2.2 Test Equipment: CHROMA 6630.
1.3 Electrical:
This section describes the electrical requirement of the monitor. Below is the block diagram.
Led drive
19V
AC-IN
100V-240V
Flat Panel and
LED backlight
Main Board
Video signal, DDC
HOST Computer
Key Board
Adapter