Z500
Service Guide Level1~2
42
Version 1.0
Step1: Put the phone on the test fixture, set the PS cal=1.5 cm
Step2:make the phone ,then select “Test PS black card CT”
Step3:make the phone cover(0.8cm), then select ” Test PS black card 0.8cm”
Step4:test Light Sensor,when the light source is 100~600,it can be pass
Note :when G-sensor & ALSPS are pass simulaneously,Auto Sensor will be pass
Hall sensor.
Put the flip cover the hall sensor of the phone,then take away,it will be over when the close and open
are pass simulaneously
Note:if G sensor/ ALSPS/ Hall sensor are pass, it doesn’t test only to clear report