H5350
Confidential
4-5
Inspection item
- Dark blemish check.(dirty)
Criteria
- The bright blemish is unacceptable when it ap
-
pears on blue 60 pattern.
- Ref. below table
Note: The defect criteria follows TI specification.
4. Dead Pixel (Bright pixel)
Procedure
- Test equipment: video generator.
- Test signal: analog 1280 x 720@60Hz.
1280 x 720@60Hz..
- Test Pattern: full black
Inspection item
- Bright pixel check.
Note: Frame dimension under operative zone1
inch
Criteria
- Bright pixel is unacceptable.
- Ref. below table
Note: The defect criteria follows TI specification.
5. Dead Pixel (Dark pixel)
Procedure
- Test equipment: video generator.
- Test signal: analog 1280 x 720@60Hz.
1280 x 720@60Hz..
- Test Pattern: full white
Inspection item
- Dead pixels check.
- White pattern (IRE=100)
- Adjacent dark pixel.
Criteria
- The number of the dead pixels should be less or
equal to 6 pixels.
- Adjacent pixel with each other is unacceptable.
- Ref. below table
Note: The defect criteria follows TI specification.
6. Focus test
Procedure
- Test equipment: video generator.
- Test signal: analog 1280 x 720@60Hz
1280 x 720@60Hz
Full black
Full white
Summary of Contents for H5350 Series
Page 14: ...H5350 Confidential 1 Remote Control and Control Panel Layout ...
Page 18: ...H5350 Confidential 1 13 ...
Page 19: ...H5350 Confidential 1 14 Bottom Cover Dimension ...
Page 88: ...H5350 Confidential II 5 3 ASSY LAMP DRIVER MODULE H5350 1 2 4 6 ...
Page 90: ...H5350 Confidential IV ASSY MAIN BD MODULE H5350 13 10 ...
Page 93: ...H5350 Confidential VII ASSY HOUSING MODULE H5350 ...
Page 95: ...H5350 Confidential IX BUY ASSY TOP COVER ADD PAINT H5350 ...
Page 101: ...H5350 Confidential XV A K H5350 8 7 9 1 2 3 4 5 6 10 ...
Page 103: ...H5350 Confidential XVII D C H5350 6 5 3 4 1 2 7 8 9 ...
Page 105: ...H5350 Confidential XIX D P H5350 19 12 9 4 3 1 13 11 18 10 17 15 6 7 8 14 2 16 5 ...