- 36 -
VESA
1152x864@75Hz
1600x900
67.5
75
108
1280x960@60Hz
1800x1000
60
60
108
SXGA
1280x1024@60Hz
1688x1066
63.981
60.020
108.000
VESA
1280x720@60Hz
1650x750
44.955
59.940
74.176
WXGA
1280x800@60Hz
1680x831
49.702
59.810
83.500
1360x768@60Hz
1792x795
47.712
60.015
85.500
WXGA+
1440x900@60Hz
1904x931
55.935
59.887
106.500
WSXGA+
1680x1050@60Hz
2240*1089
65.290
59.954
146.250
UXGA
1600x1200@60Hz
2160x1250
75.000
60.000
162.000
1920x1080@60Hz
2576x1120
67.158
59.963
173.000
1920x1080@60Hz
2200x1125
67.500
60.000
148.500
1920x1080@60Hz
2080x1111
66.587
59.934
138.500
5.1.3 ADC calibration (Auto color balance adjustment)
~~
Analog
only, it is not required for DVI-D input source
1. Setup input timing ICL-605( 1280x1024@75Hz ), pattern 42(5-Mosaic pattern with white color block)
with Analog signals from Chroma video pattern generator. (it depends on Scaler IC supplier’s
recommendation)
2.
Enter factory mode (press “Empowering” & “Power” buttons at the same time to turn on monitor).
3. Mov
e cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4.
Close OSD menu then press “Auto” button for auto color adjustment. (This procedure will get optimal
gain/offset(clamp) values)
5. Checking if the picture is ok, or reject this monitor and check its circuit board or wire/cable connection.
5.1.4 Color temperature adjustment
1. Setup input timing to any preset modes, pattern 41(full white color pattern) with Analog signals from
Chroma video pattern generator.
2.
Enter factory mode (press “Empowering” & “Power” buttons at the same time to turn on monitor).
3.
Move cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4. Make sure ADC calibration (auto color balance adjustment) had already been done.
5. Measure color temperature by Minolta CA-110 (or equivalent equipment).
6. Adjust the color temperature ~~ Two methods can be used to adjust RED, GREEN, BLUE value of
each color temperature, C0/Cool, C1/User & C2/Warm to meet following spec requirement, the 1
st
method is by using external PC and IIC alignment protocol to do automatic adjustment, and the 2
nd
method is by manually and must be in factory mode.
Color temperature
X+-
0.283+(-) 0.03
Y+-
0.297+(-) 0.03
Summary of Contents for G225HQ
Page 22: ... 22 3 9 Packing ...
Page 23: ... 23 4 Disassembly Assembly 4 1 Exploded View ...
Page 24: ... 24 ...
Page 46: ... 46 5 4 OSD Operation Guide ...