10
Chapter 1
Environmental Requirements
Power Management
•
Devices wake up from S3 should be less than.
•
Devices wake up from S5 should be less than 10 seconds.
Item
Specification
Temperature
Operating
+5°C ~ +35°C
Non-operating
-20 ~ +60°C (Storage package)
Humidity
Operating
15% to 80% RH
Non-operating
10% to 90% RH
Vibration
Operating (unpacked)
5 ~ 500 Hz: 2.20g RMS random, 10 minutes per axis in all 3 axes.
5 ~500 Hz: 1.09g RMS random, 1 hour per axis in all 3 axes.
Devices
S1
S3
S4
S5
Power Button
V
V
V
V
USB Keyboard/Mouse
V
V
N/A
N/A
PME
Disabled
Disabled
Disabled
Disabled
RCT
Disabled
Disabled
Disabled
Disabled
WOR
Disabled
Disabled
Disabled
Disabled
Summary of Contents for Aspire X3470
Page 1: ...Acer Aspire X3470 Service Guide PRINTED IN TAIWAN ...
Page 12: ...4 Chapter 1 Block Diagram ...
Page 59: ...51 Chapter 3 3 Lock the CPU cooler 4 Connect the cooler cable to the main board ...
Page 65: ...57 Chapter 3 Install the I O Shielding 1 Install I O shielding into chassis ...
Page 73: ...65 Chapter 3 Install the VGA Card 1 Press down the VGA card ...
Page 75: ...67 Chapter 3 Install the Side Panel 1 Install the side Panel then fix two screws ...