Hardware Specifications and Configurations
1-37
System Power Management
Item
Specification
Mech. Off (G3)
Al devices in the system are turned off completely.
Soft Off (G2/S5)
OS initiated shutdown. All devices in the system are turned off
completely.
Working (G0/S0)
Individual devices such as the CPU and hard disc may be
power managed in this state.
Suspend to RAM (S3)
CPU set power down
VGA Suspend
Audio Power Down
Hard Disk Power Down
CD-ROM Power Down
Super I/O Low Power mode
Save to Disk (S4)
Also called Hibernation Mode. System saves all system states
and data onto the disc prior to power off the whole system.
Summary of Contents for Aspire M5-481PT
Page 1: ...Acer M5 481 481G 481T 481TG SERVICE GUIDE ...
Page 8: ...viii ...
Page 9: ...CHAPTER 1 Hardware Specifications ...
Page 10: ...1 2 ...
Page 54: ...1 44 Hardware Specifications and Configurations ...
Page 55: ...CHAPTER 2 System Utilities ...
Page 56: ...2 2 ...
Page 73: ...Acer M5 481 481G 481T 481TG System Utilities 2 19 Figure 2 19 InsydeFlash ...
Page 83: ...CHAPTER 3 Maintenance Procedures ...
Page 84: ...3 2 ...
Page 91: ...3 9 Figure 3 2 Lower Cover Cabling ID Size Quantity Screw Type A M2 5x5 0 15 ...
Page 95: ...3 13 ID Size Quantity Screw Type M2 5 x 1 x 7 Flat head 2 ...
Page 103: ...3 21 ID Size Quantity Screw Type M2 0 x 2 0 1 ...
Page 105: ...3 23 ID Size Quantity Screw Type M2 0 x 2 0 1 ...
Page 113: ...3 31 ID Size Quantity Screw Type A M2 0 x 2 0 2 B M2 0 x 2 0 2 ...
Page 116: ...3 34 Figure 3 2 Fan Thermal Assembly Removal ...
Page 118: ...3 36 ID Size Quantity Screw Type A M2 0 x 0 5 x 7 0 Flathead 3 B M2 0 x 0 5 x 7 0 Flathead 3 ...
Page 122: ...3 40 ID Size Quantity Screw Type A M2 0 x 0 5 x 7 0 flathead 2 ...
Page 132: ...3 50 ID Size Quantity Screw Type A M2 5x5 0 15 ...
Page 138: ...3 56 Figure 3 2 Audio Board Screws Removal ID Size Quantity Screw Type M2 0 x 3 0 2 ...
Page 143: ...3 61 ID Size Quantity Screw Type M2 0 x 2 0 1 ...
Page 148: ...3 66 Figure 3 3 MIC Cable Positioning ...
Page 153: ...3 71 Figure 3 2 Fan Thermal Screw Removal 1 3 2 4 5 6 ...
Page 159: ...3 77 Figure 3 3 LVDS Alignment ...
Page 162: ...3 80 ID Size Quantity Screw Type M2 5 x 3 0 3 ...
Page 166: ...CHAPTER 4 Troubleshooting ...
Page 167: ...4 2 ...
Page 188: ...CHAPTER 5 Jumper and Connector Locations ...
Page 189: ...5 2 ...
Page 191: ...5 4 ...
Page 192: ...CHAPTER 6 FRU Field Replaceable Unit List ...
Page 193: ...6 2 ...
Page 206: ...CHAPTER 7 Model Definition and Configuration ...
Page 207: ...7 2 ...
Page 233: ...7 28 Model Definition and Configuration ...
Page 234: ...CHAPTER 8 Test Compatible Components ...
Page 235: ...8 2 ...
Page 243: ...8 10 Test Compatible Components ...
Page 244: ...CHAPTER 9 Online Support Information ...
Page 245: ...9 2 ...
Page 247: ...9 4 Online Support Information ...