Acer S205F / S200F User’s Manual
32
Notes
1 Drives are numbered row/column.
2 With only one active PSU the enclosure will take approximately 96 seconds to start
all drives from Power On.
)
Important
SES drives: Drive bay set for immediate start, all other bays are delayed spin start (12 seconds x
Module 8 of the SEL_ID) unless there are two active PSUs when they all start immediately.
2.9 Altos S200F Drive Enclosure
Device Addressing
Each enclosure has 16 drive bays. The SEL_ID of each drive is determined by the device slot (0-15) in
which it is installed and the address range setting, which is set by means of the Enclosure ID switch
on the Ops Panel (shown in
) at the rear of the enclosure. The switch settings
are shown in
Table 2–4
Drive Slot Arrangement: Enclosure Front View
Column / row
1/#
2/#
3/#
4/#
#/1
Drive 0*
Drive 1
Drive 2
Drive 3
#/2
Drive 4
Drive 5
Drive 6
Drive 7
#/3
Drive 8
Drive 9
Drive 10
Drive 11
#/4
Drive 12
Drive 13
Drive 14
Drive 15*
Table 2–5
Ops Panel Switch Functions
Switch Number Function
Recommended Setting
Definition
1
Not Used
Off
2
Not Used
Off
3
Not Used
Off
4
Not Used
Off
5 & 6
Not Used
Off
7 & 8
Drive Loop Speed
Select
Sw 7
Sw 8
On
Off
Force 2Gb/s
Off
Off
Force 1Gb/s
9 & 10
Drive Addressing
Mode Selection
Sw 9
Sw 10
On
On
Mode 0 (recommended)
Off
On
Mode 1 (not recommended)