Appendix B Rack installation guide
102
Vertical mounting hole pattern
The four vertical rails of a rack contain mounting holes arranged in a
manner shown in the figure below:
The system occupies 5U in the rack. Count the U positions and hole
numbers from the bottom up.
Note:
The unit of measurement used in this document is "U"
(1U = 1.75 inches or 44.45 mm). The total sum of the heights of all
components in the rack measured in "U" cannot exceed the
height of the rack. For more information, refer to the
documentation that came with your system rack.
The distance from the center of two holes with closer spacing to the
center of the next pair is equivalent to 1U.
When installing components, you must start your measurement from
the center of the two holes with closer spacing. Otherwise, the screw
holes on the component may not match those on the rack.
AA G701 - EN.book Page 102 Monday, March 17, 2003 4:24 PM
Summary of Contents for Altos G701
Page 1: ...Acer Altos G700 series User s guide Model G701 ...
Page 10: ...x ...
Page 11: ...1 System tour ...
Page 25: ...2 System setup ...
Page 39: ...3 Upgrading the system ...
Page 67: ...4 BIOS setup ...
Page 74: ...4 BIOS setup 64 System Information ...
Page 75: ...65 Total Memory ...
Page 102: ...4 BIOS setup 92 ...
Page 103: ...Appendix A ASM RDM quick installation guide ...
Page 104: ...This appendix shows you how to install the ASM and RDM software package ...
Page 110: ...Appendix A ASM RDM quick installation guide 100 ...
Page 111: ...Appendix B Rack installation guide ...
Page 112: ...This appendix shows you how to install the ASM and RDM software package ...