11. ENVIROMENT REQUIREMENT
11.1
Operating
Temperature 5
°
C ~ 40
°
C
Relative Humidity
20% to 80%
Altitude
Sea level to 8000ft
11.2
Storage or Shipment
Temperature -20
°
C ~ +60
°
C
Relative Humidity
5% to 85%
Altitude
Sea level to 40,000ft
11.2.1
TEST PROCEDURE:
•
Put in temperature chamber under 60
°
C
Time:24 hours
•
Back to room temperature
Time: 4 hours
•
Put in temperature chamber under -20
°
C
Time:24 hours
•
Back to room temperature
Time:4 hours
•
The process repeat 2 times.