10
Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
:
Dark room
Viewing distance
:
40 cm for LCD performance, 20 cm for LCD failures
Warm up time
All specifications
:
>
30 minutes
Fully functional
:
5 seconds
Measuring equipment
:
Chroma 7120 signal generator or equivalent, directly
Connected to the monitor under test.
Control settings
Minolta CA100 photometer, or equivalent
User brightness control
:
Set to Factory preset value (cut off raster)
User contrast control
:
T Set to factory preset value, which allows that the
brightest two of 32 linear distributed gray-scales (0
~
700mv) can be distinguished.
User red/white balance,
Green/white balance and
Blue/white balance control
:
In the center (unless otherwise specified)
Power input
:
230V
±
5
%
Ambient temperature
:
20+5
℃
Analog input mode
:
1280x1024, 60 Hz, all white
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
lb = kg x 2.2
degrees F = [°C x 1.8] + 32
degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76
Summary of Contents for AL1751
Page 1: ...Acer AL1751 Service Guide ...
Page 17: ...17 Main Board Layout ...
Page 19: ...19 Front Bezel ...
Page 20: ...20 ...
Page 21: ...21 Rear Bezel ...
Page 22: ...22 Adjusting the Picture ...
Page 23: ...23 ...
Page 24: ...24 b The Description For Control Function ...
Page 25: ...25 ...
Page 30: ...30 Fig 7 Fig 8 ...
Page 31: ...31 Fig 9 ...
Page 40: ...40 Exploded Diagram Model AL1751 ...
Page 43: ......
Page 51: ...51 Adapter Board ...