background image

 

SET UP YOUR LCD MONITOR

 

Installation 

Note

: Please read last section “ Safety” before you install the LCD Monitor.   

Notes 

Please note the instruction below prior to installing your LCD monitor. 

Installation Position 

Choose a position where the reflection of light is minimal and away from a window for 
maximizing the quality of the screen image. 

It is important to keep 30 cm between the LCD monitor to minimize eyestrain. 

Workstation Height 

Position the LCD monitor slightly above your horizontal vision as you are sitting. 

Angle of Vision 

Tilt either forward or backward for the most comfortable viewing angle. 

Quick Installation 

This LCD monitor supports connection to a computer or workstation. The steps are 
described as Quick Setup. 

 

After installation, please refer to “Auto Adjust” for automatic adjust procedures. 

Screen 
Adjustments 

 

Auto Adjust 

Though your computer system can identify the new LCD monitor system, the Auto Adjust
function can be as to enhance the display. To enter adjust mode, please refer to “OSD 
Control”. 

 

 

 

Turn the computer and LCD monitor on. 

Press ‘Auto’ button to start Auto Adjust. 

The LCD monitor will start the Auto Adjust process automatically for 10 consecutive 

seconds, where you will notice the image change as the Auto Adjust is working. 

Self Test Function 
Check (STFC): 

Your LCD monitor provides a STFC function, through which you can check whether 
the LCD monitor functions are working properly. 

If your LCD monitor is properly connected, but there is no image showing and the 
indicator light keeps orange, please follow the steps below to start STFC. 

 

Shutdown computer and LCD monitor. 

 

Unplug the signal connector from the back of computer. 

 

Turn the LCD monitor on. 

 

 

If the image connector is disconnected or damaged, the image shown on following 

figure will also appear during normal operation. 

 

 

 

 

Turn off the LCD monitor and reconnect signal cable, and then turn the
computer and LCD monitor on. 

 

 

If the LED of the LCD monitor is an orange color after completing the steps above, 
please check your VGA card and computer system. Your monitor should be 
operating properly. 

 

E

n

g

lis

h

 

 

 

 

 

 

 

 

4

Summary of Contents for AL1703

Page 1: ...ntents PRODUCT 2 Contents 2 Features 2 Power saver 2 Plug play 2 SAFETY 3 Electrical 3 Common 3 SET UP YOUR LCD MONITOR 4 Installation 4 Screen Adjustments 4 OSD Control 5 TROUBLE SHOOTING 8 MAINTENANCE 9 ...

Page 2: ...er Slight moving or any click will return to the original image The VGA card inside the computer handles Power Saver You can use computer software to set the function The LCD Monitor is compatible with EPA ENERGY STAR and NÜTEK if used with a VESA DPMS computer To save power turn off the power of the LCD monitor when not in use Plug play The new VESA Plug and Play function is used which eliminates...

Page 3: ...ed to clean the monitor by first turning it off and using a soft dry cloth The LCD monitor should be placed in areas with low humidity and less dust Please watch out for environmental conditions on humidity and ventilation The LCD monitor should be kept away from heat sources and irradiation For example kitchen oven or direct sunlight and etc To reduce glare avoid placing the monitor in a place th...

Page 4: ...as to enhance the display To enter adjust mode please refer to OSD Control Turn the computer and LCD monitor on Press Auto button to start Auto Adjust The LCD monitor will start the Auto Adjust process automatically for 10 consecutive seconds where you will notice the image change as the Auto Adjust is working Self Test Function Check STFC Your LCD monitor provides a STFC function through which yo...

Page 5: ... Orange Power Saving Off Power Off 2 Auto Exit Automatically optimize positions phase clock when OSD is not shown Exit the OSD menu when OSD is shown Turbo Quick brightness switching 3 Input Turbo optional D Sub DVI input source selection 4 Selection or adjustment when OSD is shown Quick brightness adjustment 5 Adjustment when OSD is shown Quick contrast adjustment 6 Menu Enter OSD Access sub menu...

Page 6: ...ng the setting of other functions V Position 50 Notes The OSD disappears several seconds after you stop pressing the buttons while performing an adjustment Any changes are automatically saved in the memory when the OSD disappears Turning off the power should be avoided while using the menu Adjustments for clock phase and positions are saved for each signal timing Except for these adjustments all o...

Page 7: ... Timeout Adjust OSD display time setting OSD Position Move OSD display position to any one of the following 5 positions within the overall screen Auto Setting Set up to adjust clock phase and positions automatically Recall Restore to factory settings Input Source Analog Select Analog input source Optiona l Digital Select Digital input source Direct You can skip the Menu pages and display an adjust...

Page 8: ...value with the preset values Please refer to Appendix Display Mode Fuzzy image Adjust Phase Image too bright Image too dark Adjust brightness and contrast by OSD Irregular image Check the signal connection between the computer and LCD monitor Perform Auto Adjust Distorted image Reset the LCD monitor perform the Recall function by OSD Take off extra accessories such as signal extension cord Image i...

Page 9: ...ner Pure water or non ammonia non alcohol based glass cleaner Do not use ketene such as acetone ethanol toluene acetic acid methane chloride or abrasive detergent to clean the monitor because those chemicals can damage the LCD monitor Screen To clean your LCD monitor screen use water or mild cleaner as above to gently moist a soft clean cloth If possible use a special screen cleaner sheet or a sol...

Reviews: