Troubleshooting
Chapter 4
This chapter provides troubleshooting information for the AL1702W:
1. No Power
No power
Press power key and look if the
picture is normal
NG
NG
Reinsert or check the
power section
Please reinsert and make sure the
AC of 100-240 is normal
OK
Check if X401 oscillate
waveforms are normal
OK
NG
Replace U201
OK
OK
NG
Replace X401
Replace U401
Measure CN201 Pin3=5V?
Measure U201 Pin 3=5V, U201 Pin
2=3.3V
if the picture is normal
NG
Replace U501