1-2
API Confidential
No Copy/Reproduction Allowed
7277e Monitor Service Guide
1.2 Operational Specification
1.2.1 Environment
1.2.1.1 Temperature
-Operating
5 to +40 degrees Celsius
-Non-operating
-20 to +60 degrees Celsius
1.2.1.2 Humidity
-Operating
20% to 90% non-condensing
-Non-operating
10% to 90% non-condensing
1.2.1.3 Altitude
-Operating
0 to 3,048m (10,000ft)
-Non-operating
0 to 12,192m (40,000ft)
-Operating condition / without packing
-Non-operating condition / with packing
1.2.2 Vibration
Package, Non-Operating
-5--26.6Hz : 0.6G
-26.6--50Hz: 0.016"
-50--500H
: 2G
-Total Test Time :
312min
(104min/Axis for X, Y, Z)
After test, there is no electrical and mechanical damage permitted.
1.2.3 Drop Test (with packing)
1.2.3.1 Drop Height
PKG. Gross Wt.
No. of Drops
Drop Height
41 - 60.991b(18.7-27.7kg)
10
24"(61cm)
1.2.3.2 Drop Sequence
2
1
5
3
4
6
Surface
2. Front
3. Bottom
4. Rear
5. Left
6. Right
1. Top
Manufacturing
joint
-Corner 5-3-2 select at weakness side [the low left(or right) corner of the front panel]
-An edge drop with impact on the shortest edge radiating from corner 5-3-2
-An edge drop with impact on the next shortest edge radiating from corner 5-3-2
-An edge drop with impact on the longest edge radiating from corner 5-3-2
-A flat drop with impact on the rear
-A flat drop with impact on the front
-A flat drop with impact on the right
-A flat drop with impact on the left
-A flat drop with impact on the bottom
-A flat drop with impact on the top
After test, there is no electrical and mechanical damage permitted.
1.2.4 Electrostatic Discharge Requirements
The subject product must withstand 15kv test voltage of electrostatic discharge and meet the