Time-slot configuration of E1 port: 

For E1 time-slot configuration, the DIP Switch settings on

 the bottom panel are as follows:

The time-slot DIP switches located at the bottom of the equipment marked with TS0~TS31 
bits corresponding to 0~31 time-slots of E1 channel.

Note:

 It is recommended to set the TS0 DIP switch OFF.

3.     Bottom Panel:

The Bottom panel of the E1/4*10(100)Base-T 4Ethernet over E1 (IPoTDM) equipment is as 
follows.

Working Mode

Switch Setting

Unframed

All switches are set to OFF

Framed (CCS/PCM-31)

S0 set to OFF, and the occupied time slots to ON

Multi-Framed (CAS/PCM-30 )

All switches S0~S31 set to ON but S16 is set to OFF

Example 1: 

If you wish to use only first 5 time-slots then you need to set the S0 time-slots to 

OFF and switch S1 to S5 to ON and time-slot S16 will be set to ON.

Example 2: 

If you wish to carry first 8 time-slots on 512Kbps, then you need to set the S0 time-

slot OFF and switch S1 to S8 to ON (i.e. since each time-slot consumes 64Kbps, so 8 time-slots 
will consume 8 x 64Kbps = 512Kbps) and time-slot S16 will be set to ON. 

Example 3: 

If you wish to carry 20 time-slots on 1.28Mbps (64Kbps x 20) then you need to set 

time slot S0 OFF and S1 to S21 time-slots to ON. Please remember that the time-slot S16 will 
be used as signaling time-slot.

11

AceCom Networks Pte Ltd.

Summary of Contents for VCL-4 Ethernet over 1E1

Page 1: ...00 Base T Interface Converter Data Sheet User Manual AceCom Networks Pte Ltd 200 Jalan Sultan Textile Centre S 199018 02 13 ingapore Phone 65 6295 3233 Fax 65 6295 3133 E mail sales acecomnet com Web...

Page 2: ...r E1 E1 4 10 100 Base T Interface Converter is an ethernet extension device utilizing TDM telecom infrastructure the telecom network of E1s or of PDH SDH and E1 E3 SDH microwave etc carrying E1s The V...

Page 3: ...VLAN switch must be OFF The ethernet ports are not isolated to each other on both sides of the E1 link Note Each DIP Switch is ON in downside and OFF in Upside VLAN Switch OFF POWER POWER PWR VCL 4 E...

Page 4: ...r example the Ethernet Port 1 at local site will communicate to Ethernet Port 1 at far end site and so on for Port 2 etc Example In the discrete link mode the LAN 1 Ethernet Port 1 of the equipment on...

Page 5: ...ed in IEEE 802 1Q and supports Ethernet switches with VLAN function 8 Imbedded dynamic Ethernet MAC address list 1024 addresses and filter function for local data frames 9 Can support multiple LANs of...

Page 6: ...nded to earth for protection 3 Installation Step 1 Power up the Ethernet over E1 IPoTDM equipment Important Please ensure that Ethernet over E1 IPoTDM equipment is powered up prior to connecting the e...

Page 7: ...OWER 1 2 3 4 5 6 7 8 L C K RLOP AUTO PD S DPX D SP L1 SPDL2 VLAN Description of the Front Panel 1 Front Panel Outline of the front panel of E1 4 10 100 Base T Interface converter is as follows Power L...

Page 8: ...ice 10M service 10M service mode mode mode mode Dup Col ON Port under Port under Port under Port under Solid full duplex full duplex full duplex full duplex mode mode mode mode Dup Col OFF Port under...

Page 9: ...g in semi duplex mode 6 and 7 Speed Limit configuration of Ethernet Interface SPLD 1 SPLD 1 SPLD 2 Port Speed limit ON and SPLD 2 ON ON None port is speed limit ON OFF 1 and 2 port speed limit 512 K 3...

Page 10: ...ut PIN No Definition of function Signal Direction 1 NC 2 TX transmitted data E1 Data Output 3 TX transmitted data E1 Data Output 4 NC 5 NC 6 RX received data E1 Data Input 7 RX received data E1 Data I...

Page 11: ...slots to ON Multi Framed CAS PCM 30 All switches S0 S31 set to ON but S16 is set to OFF Example 1 If you wish to use only first 5 time slots then you need to set the S0 time slots to OFF and switch S1...

Page 12: ...1LOS E1SYL and AIS shall be OFF 1 Trouble E1LOS light ON Check point make E1 loop back at E1 input port and output port if the light OFF then highlight the check on E1 input line Please check with the...

Page 13: ...k point This fault may be due to the following reasons 1 Incompatible configuration of E1 port impedance 2 Incomplete physical connection of E1 port e g only one pole connected at receiving end 3 Wron...

Page 14: ...lease consult the provider or contact our SUPPORT DESK at support valiantcom com helpdesk valiantcom com Technical specifications are subject to changes without notice Windows is the registered Tradem...

Reviews: