V2.4
19 |
P a g e
ACE RELIANCE SENSOR OPERATIONS MANUAL
Figure 33
1kPSI sensor model and the TEC cable are ready to be connected
WARNING: The ACE ¼” Gauge Strip must be used to cut TEC cable for the 1kPSI model. If ACE Dual Seal TEC Strip
Gauge is used, this may cause to well fluid leak into the sensor and a failure. Please see the pictures of the two
types of ACE TEC strip gauges at the beginning of this manual.
6. Sensor and cable Integrity testing
During pressure testing in the shop, after the sensor and cable have been mated and been under pressure for
some time, use Fluke 1507 Insulation tester at the 1000V setting to verify 11 GOhm insulation resistance;
anything below that indicates a fluid transgression at some point (or insulation breakdown in the cable on the
spool).