Chapter
4 Configuration
Installation and Operation Manual
4-70
Configuring for Operation
ACE-3105, ACE-3205 Ver. 5.2
Configuring OAM Loopback Parameters
The OAM loopback function allows ACE-3105, ACE-3205 to send OAM loopback
cells in case of a link failure. The OAM loopback configuration menu allows you to
define the loopback source address and failure threshold.
³
To access the OAM loopback configuration menu:
•
From the ATM menu (see
), select OAM.
The OAM configuration menu is displayed.
ACE-3205 – RAD Data Communications
Configuration> Applications> ATM> OAM
1. OAM descriptor (OD) >
2. Loopback source address ... (00000000000000000000000000000001)
3. Loopback failure threshold ... (1)
>
Please select item <1 to 3>
ESC-previous menu; !-main menu; &-exit
Figure
4-52. OAM Menu
Table
4-45. OAM Parameters
Parameter Description
Possible
Values
OAM descriptor
(OD)
Access the OAM descriptor options
See
below
Loopback source
address
The unit's OAM loopback source address.
For more information about the OAM loopback
functionality, refer to
Appendix C
.
00–FF
°
16 (Hex)
Default:
See
above
Loopback failure
threshold
Number of lost loopback cells before a
loopback failure state is declared.
1–16
Default: 1