background image

About AM100 plus SMBG System

 

 

11 

 

Component Description

 

Lancing Device

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Lancets

 

 

 

 

Protective Cap    Needle     Handle

 

Depth Settings & Indicator

 

 

Release Button

 

Cocking Handle

 

Summary of Contents for ACEZIN GLUGlod

Page 1: ...User s Manual ACEZIN GLUGlod Blood Glucose Monitoring System A Model No AM100 plus...

Page 2: ......

Page 3: ...results possible please read the entire User s Manual before testing This package contains 2 new AAA alkaline batteries Insert them into AM100 plus Blood Glucose Monitoring System by following steps i...

Page 4: ...ren They may choke on battery or tiny component parts by accident Keep AM100 plus Blood Glucose Meter free from dust hair etc Store the meter in its container after use If you feel you are suffering f...

Page 5: ...devices Consult instructions for use In vitro diagnostic medical device Use by date Manufacturer Date of manufacture Temperature limit Humidity limitation Keep away from sunlight Do not re use Batch...

Page 6: ...for Testing 14 Battery Installation Presetting Date and Time Quality Control of the System 16 Using Glucose Control Solution Perform the Blood Glucose Test 18 Perform the Blood Glucose Test LO and HI...

Page 7: ...en after cleaning should be handled as if capable of transmitting viral disease Test results below 70 mg dl 3 9 mmol l mean low blood glucose hypoglycemia Test results greater than 240 mg dl 13 3 mmol...

Page 8: ...Blood Glucose Test Strips Measuring Principle We design AM100 plus Blood Glucose Monitoring System by using the latest biosensor technology It measures the glucose levels of the blood specimen by usin...

Page 9: ...r s Manual for AM100 plus Blood Glucose Monitoring System 2 Quick Reference Guide 3 Logbook Note Please consult your provider local distributor for extra Blood Glucose Test Strips and Glucose Control...

Page 10: ...ucose Meter LCD Screen Displays blood glucose results messages and glucose results stored in memory M Button Press to enter different mode Test Strip Slot Insert test strip here Strip Eject Button Pre...

Page 11: ...erature 4 Day or Year 9 Decimal Point Appears when LCD displays blood glucose result in mmol l unit 14 Control Solution Test Symbol Appears while performing Control Solution Mode 5 MEM Appear while LC...

Page 12: ...iccate reagent in the vial may cause skin or eye irritation by contact Note Only use AMG011 Blood Glucose Test Strips with AM100 plus Blood Glucose Meter only Do not touch the strip when your hands ar...

Page 13: ...About AM100 plus SMBG System 11 ComponentDescription Lancing Device Lancets Protective Cap Needle Handle Depth Settings Indicator Release Button Cocking Handle...

Page 14: ...its user to better manage the glucose control plan also your healthcare professional by providing data when diagnosing and prescribing Follow below steps to activate Meal Comment Function Under Standb...

Page 15: ...lts simply remove test strip from test strip port after measurement ends Meter will automatically store your test result in its memory with previous set symbol With Meal Comment Function on Pre meal T...

Page 16: ...rrect polarities Put the battery cap back To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipment do not use the device near a mobile phone or mi...

Page 17: ...to enter Setting Mode Note After battery replacement meter automatically activates Setting Mode 2 When YEAR digits flash press S button to select current year When done press M button to confirm To co...

Page 18: ...when to perform a control solution test Handling your meter at the first time After opening a new vial of test strips Strong impact on the meter When your symptoms do not agree with the way you feel...

Page 19: ...mination do not apply the control solution to the test strip directlyfromthebottle Note Check the Test Strip vial for acceptable ranges for High and Medium Levels Refer to Glucose Control Solution ins...

Page 20: ...ancing device and lancets with other people The lancet is for single use only Never reuse them Be sure to save the protective cap of the lancet for later use Remember to put it back on to the lancet b...

Page 21: ...verage skin 5 6 for thick or calloused skin 5 Pull the cocking handle out until it clicks 6 Wash hands first or use an alcohol swab to wipe your finger clean Wait until your hands are totally dry 7 In...

Page 22: ...sample 9 To avoid body fluid contamination wipe off the first drop of blood with a clean gauze or cotton Gently squeeze the fingertip to obtain the second drop of blood for testing 10 With symbol on y...

Page 23: ...false or inaccurate result Your Test Strip doesn t have enough blood sample on it An unfilled collection zone may lead to false or inaccurate result A totally filled collection zone Do not drip your...

Page 24: ...n the setting 16 User can either take out the used strip by pushing and slide the Strip Eject button or remove the test strip directly to shut the meter off Without any operation for 2 minutes the met...

Page 25: ...stored in the memory but does not count in the average of last 7 14 30 60 days Importantinformation LO reading with symptoms If you have LO test results and also symptoms such as weakness sweating ne...

Page 26: ...for example While displaying average results 07d on the upper left represents the result displaying now are from last 7 days 021 on the upper right represents how many results are performed during la...

Page 27: ...st 60 days 6 To view the records in the memory press M button again the meter start displaying each test result with memory sequence number and then corresponding date and time 7 8 Keep pressing M but...

Page 28: ...nd M buttons for 3 seconds the screen will show dA for confirmation 2 Press S button again for 3 seconds to delete all records Or if you want to check out the delete function press M button to return...

Page 29: ...ring results to other Wireless Transmission device please redo steps 1 2 4 Note Please do not turn on more than one Wireless transmission function of glucose meters AM100 plus is subject to and compli...

Page 30: ...one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different...

Page 31: ...disinfect it follow these guidelines carefully to help you get the best performance possible 1 Make sure the meter is turned off 2 Gently wipe the meter s surface with a soft cloth slightly dampened...

Page 32: ...ing System at room temperature between 10 C 40 C 50 F 104 F Out of this range the device just won t work 4 Extreme humidity may affect the results A relative humidity greater than 80 may cause incorre...

Page 33: ...55 C 40 F 131 F R H 90 Strip 4 C 30 C 39 2 F 86 F R H 90 Transportation Condition Meter 40 C 55 C 40 F 131 F R H 90 Package with Strips 4 C 30 C 39 2 F 86 F R H 90 Blood Volume 1 0 l Sample Type Capil...

Page 34: ...ogy increases the effective data rate and integrity in noisy environments Security AES 128 and application layer user defined Operating Distance Class 2 Maximum 10 meter RF Frequency Need for Spectrum...

Page 35: ...If Er 2 appears constantly please call Ace Medical Technology Co Ltd or authorized distributor in business hours Er 3 appears when your Test Strip does not have enough blood sample on it Repeat the te...

Page 36: ...F The meter is unable to measure Do not artificially heat or cool the meter Leave your meter in a room around 10 C 40 C 50 F 104 F for 15 minutes then repeat the test See Perform the Glucose Blood Tes...

Page 37: ...ose Test Strips ACEZIN GLUGold Glucose Control Solution ACEZIN Lancing Device ACEZIN Lancets Ace Medical Co Ltd No 52 DinghuRoad GuishanDistrict 33378 TauyuanCity Taiwan R O C Tel 886 3 327 8180 Fax 8...

Page 38: ...h Dist Taichung City Taiwan Tel 886 4 22601991 http www medifuncorp com Lancets Meets the requirement of MDD 93 42 EEC Tianjin Huahong Technology Co Ltd A 01 Plant B No 278 Hangkong Road Tianjin Pilot...

Page 39: ...rly because of a defect in materials or workmanship Ace Medical Technology Co Ltd SERVICE will repair the meter or replace it with a new ACEZIN GLUGold AM100 plus Blood Glucose Meter or equivalent pro...

Page 40: ...P N M709 000000 XXX VER 001...

Reviews: