AccuTools eL-520 User Manual Download Page 5

eL-520 User’s Guide 

FEATURES 

Ÿ 

If the sensor is damaged, a sweeping alarm and a red-green 
flash will indicate the problem. 

Ÿ 

A flashing LED during normal operation also reflects the 
battery level:  

 

Green

batteries are fresh 

 

Orange

batteries should be changed 

• 

If the batteries are nearly empty, the LED will turn solid red 
and a two-tone alarm will be noted for 5 seconds, before the 

eL-520 

will power itself off. 

Ÿ 

If the unit is left on unattended, it will automatically turn off 
after about 5 minutes to conserve batteries. 

 

BATTERY INSTALLATION AND REPLACEMENT 

1.  Turn the power off. 

2.  Remove the battery cover from the back of the instrument by 

loosening the battery cover screw and lifting the battery 
cover off. Be careful not to lose the extra sensor stored in the 
battery compartment. 

3.  Insert 2 size ‘AA’ alkaline batteries, observing proper battery 

polarity. 

4.  Replace battery cover and tighten battery cover screw. 

Summary of Contents for eL-520

Page 1: ...eL 520 Refrigerant Gas Leak Detector User s Guide...

Page 2: ......

Page 3: ...eL 520 will detect leaks as small as 0 1 oz yr 3g year in R12 R22 R134a and other halogen refrigerant systems The eL 520 should not be used on systems that contain flammable refrigerants such as Prop...

Page 4: ...for most leaks Press the button twice double click like a computer mouse The LED will fade from red to green and a sweeping sound effect of low to high pitch will be heard The sensitivity is now set...

Page 5: ...or 5 seconds before the eL 520 will power itself off If the unit is left on unattended it will automatically turn off after about 5 minutes to conserve batteries BATTERY INSTALLATION AND REPLACEMENT 1...

Page 6: ...ement of the sensor is necessary 1 Turn the power off 2 Locate the replacement sensor in the battery compartment 3 Unscrew turn counter clockwise the old sensor from the 4 end of the probe 5 Screw tur...

Page 7: ...y it should be wiped off with a dry shop towel or blown off with shop air No cleaners or solvents shall be used since many electronic detectors are sensitive to their ingredients 5 Visually trace the...

Page 8: ...air conditioning module shall be accomplished by turning the air conditioning blower on high for a period of 15 sec minimum shutting it off then waiting for the refrigerant to accumulate in the case...

Page 9: ...eL 520 User s Guide 7 NOTES...

Page 10: ...eL 520 User s Guide 8 NOTES...

Page 11: ...ED WARRANTIES OF MERCHANTABILITY AND FITTNESS FOR A PARTICULAR PURPOSE Core Enterprises Inc shall not be liable for any incidental or consequential damages caused by the breach of any express implied...

Page 12: ...P N 10220 Rev A 3650 Coral Ridge Drive Suite 101 Coral Springs FL 33065 Ph 954 227 0781 Fax 954 227 1094 www accutools com...

Reviews: